My WebLink
|
Help
|
About
|
Sign Out
Browse
202601609
LFImages
>
Deeds
>
Deeds By Year
>
2026
>
202601609
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/17/2026 10:53:39 AM
Creation date
3/17/2026 10:52:01 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202601609
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
CR' <br />1.0 <br />`i <br />'.0 <br />CV <br />CD <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER, OVERLASH <br />MESSENGER CABLE <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />EXISTING SLACK LOOP <br />EXISTING SPLICE CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />0 <br />0 <br />Gq <br />CO <br />0 <br />co <br />0 <br />n n <br />• <br />1515151 <br />B is Conduit Bored (i.e. 3' B) <br />C Is Conductor (Le. 3/C) <br />CC Is Coaxial Cable <br />CCC Is Camera Control Cable <br />CDC Is Camera Detector Cable <br />CG Is Circuit Ground <br />CPC Is Camera Power Cable <br />DB is Direct Buried <br />DMSC is Dynamic Message Sign Cable <br />EDC is Emergency Detector Cable <br />ETW is ElnUbic Tracer Wee <br />EX is Existing <br />File Fabric Interduct <br />FLC Is Fiber Locate Cable <br />FTW Is Fiber Tracer Wire <br />INS Is Install <br />INT Is Intraduct <br />LC Is Lead -In Cable <br />M is Conduit Mounted (i.e. 2" M) <br />MB Is Main Une Conduit Group Bored (6) 1 1/4" <br />MM is Multi Mode Fiber Cable <br />MT is Main Une Conduit Group Trenched (6) 1 1/4" <br />NO is Number <br />OH is Over Head <br />PR Is Pair of Communication (I.e. 6 PR) <br />REL is Relocate <br />REM is Remove <br />RGS Is Rigid Galvanized Steel <br />SC is Service Cable <br />SL Is Street Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched (I.e. 3" T) <br />TW Is Tracer Wire (black or green) <br />BOC Is Back Of Cum <br />EOP is Edge Of Pavement <br />PCA243636-00006 <br />PCo POLYMER OOICRIE NEWLY <br />ITZn No Floor, 42.3:°11'Nar <br />540`ier"+r1 <br />11r Wino Soo <br />n <br />LIMO RATING <br />.P. 411.10, mA.,A <br />WUC <br />• D,aPm„'n.eaw <br />• Slild rm.. angle <br />• wee.ePM m <br />Aeentrl.Pmtml.rrm <br />is, Maas <br />insist ONlnMaw <br />aATr <br />YAIm <br />XI IMP <br />Deem <br />a <br />PC?( <br />SEGRA PULL BOX, 24"X36"X36" <br />SEGRA PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 1.25" 8 <br />LF. <br />4,160 <br />TRACER WIRE <br />LF. <br />2,115 <br />SPLICE ENCLOSURE <br />EA. <br />2 <br />SEGRA PULL BOX <br />EA. <br />3 <br />TEMPORARY TRAFFIC CONTROL <br />LS. <br />1 <br />FIBER, 24 SM, UNDERGROUND <br />LF. <br />415 <br />FIBER, 24 SM, UNDERGROUND SLACK STORAGE <br />IF. <br />380 <br />FIBER, 144 SM, UNDERGROUND <br />LF. <br />2,045 <br />FIBER, 144 SM, UNDERGROUND SLACK STORAGE <br />I.F. <br />240 <br />ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTIEIE ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS AND POLES. QUANTITES DO <br />NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.• <br />PROJECT NO. <br />SHEET NO. <br />SEGRA: P059834 <br />JEO: 251901.10 <br />Date: 22-JAN-2026 <br />Drawn: BRB <br />Cb ked. JDH <br />Approved: MAF <br />SEGRA <br />DIAMOND PLASTICS CORP <br />1212 JOHNSTOWN RD <br />GRAND ISLAND, NE <br />mowwhat% below. <br />Call before you dig. <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE. <br />ELECTRIC. GAS MAINS. CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTLITIES AND DRAINAGE <br />STRUCTURES HAVE BEEN PLOTTED <br />FROM AVAILABLE INFORMATION AND <br />THEREFORE, THEIR LOCATIONS MUST <br />BE CONSIDERED APPROXIMATE ONLY. <br />IT IS THE RESPONSIBIUTY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXISTING UTILITY BEFORE AND <br />DURING ACTUAL CONSTRUCTION. <br />IEO CONSULTING GROUP INC <br />1937 N_ Chestnut Street <br />wahoo, NE 68066 <br />1.800.723,8567 <br />JEO ConeS009 Group, Inc. <br />Orgertallon Certificate of Aumodzatlon <br />Number: CA-0069 <br />
The URL can be used to link to this page
Your browser does not support the video tag.