My WebLink
|
Help
|
About
|
Sign Out
Browse
202401211
LFImages
>
Deeds
>
Deeds By Year
>
2024
>
202401211
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 10:19:01 AM
Creation date
3/25/2024 10:15:36 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202401211
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
K <br />1 <br />1 <br />1 <br />1 <br />9 <br />�5g <br />LEGEND OF SYMBOLS <br />DOSING CONDUIT <br />EXISTING AERAL FIBER <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL RBER, OVERIASH <br />MESSENGER CABLE <br />EXISTING CONDOR <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTNG UTILITY POLE <br />EASING SUCK LOOP <br />EXISTNG SPLICE GSE <br />COSTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE RT <br />ARROW PANEL <br />CABLE AND <br />CONDUIT DESIGNATIONS <br />4 <br />EA <br />LTD <br />0 <br />CB <br />0 <br />CO <br />OD <br />0 <br />—a— <br />0 <br />B b Co.. Bored Be.3' B) <br />C is conductor (e. 3/C) <br />CC is Coaxial Cable <br />CCC h Camera Conaol Cable <br />COC 6 Camera Delector Cable <br />CG h Circuit Ground <br />CPC h Camera Power Cable <br />DB is Direct Buried <br />OMISC ie Dynamic Message Sign Cable <br />FDC h Emergency Detector Cede <br />ETV Is Eleclr0 Tracer Wire <br />EX h Eddlrg <br />R h Fabric Inlotluct <br />FLC b Fiber Locate Cable <br />FTW is Fiber Tracer Wre <br />INS 6 Install <br />INT Is Intraduct <br />LC h Lead -In Cable <br />M is Conduit Mounted (6_2- M) <br />MB h Man Une Conduit Group Bored (6) 11/4' <br />AN h MUM Mode Fiber Cable <br />MT is Man Una Conduit Group Trenched (6)11/4' <br />NO Is Number <br />OH is Over Heed <br />PR is Poi of Communication (ie.. 8 PR) <br />REL is Raoale <br />REM Is Remove <br />8GS Is Rigid Galvanized Sled <br />SC Is Service Cable <br />SL 6 Sheet Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched 00..3" T) <br />IW Is Tracer Wire (beck or green) <br />PCA243636-00006 <br />POLYMER 0004ETE Ae5E401.0 <br />WaStraW <br />LOAD MIrek.iotica..ro.a let *dwelt <br />s4r•r•+e <br />r•.•ereW <br />9 n <br />UPN PULL BOX, 24'%38'X38' <br />WV I <br />b <br />NOM <br />PIM <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />BEM <br />UNIT <br />MANTIS/ <br />CONDUIT, 125' B <br />LF. <br />760 <br />TRACER VIRE <br />LF. <br />760 <br />BUILDING ENTRANCE <br />EA <br />1 <br />UPN PULL BOX <br />EA. <br />2 <br />FIBER. 96 SM UNDERGROUND <br />IF. <br />760 <br />FIBER. 96 SM. UNDERGROUND SLACK STORAGE <br />LI <br />340 <br />'ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES AR <br />MEASURED AS UNEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION ORANGE OR SLACK" <br />PROJECT NOTES <br />1. PARCEL DATA UTIUIV INFORMATION. AND AERIAL IS APPROXIMATE AND SHOULD BE <br />TREATED AS SUCH. CONTRACTOR TO LOCATE AND INSTALL IN RIGHT -OF -WAV. <br />2. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTLITY <br />FACLTTES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTLIIIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION `RLL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTLIRES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />DENTIFIED TO THE SATISFACTION OF ALL PARTES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTONS. <br />3 UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CRY, THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOK. <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW UNE <br />OF A DITCH AT A THREE (3) HORQONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48)INCFES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW UNE. AND <br />E. MAINTAIN A MINIMUM OF 24' OF VERTICAL & HORIZONTAL SPACING FROM <br />EX9TNG URURES. <br />4. ALL POTHOLES N SIDEWALK PANELS WILL REWIRE FULL PANEL REPLACEMENT <br />5. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />6. ANY CUT OR P01140LE IN A ASPHALT Suitt! LANE WLL TEOUIRE SEAM TO <br />SEAN ASPHALT MIL NG AND REPLACEMENT. <br />FRGECT NO <br />1117-0078 <br />SHEET NO. <br />GI <br />owe: cdoz.004 <br />Crum JAS <br />dreUed- 1818 <br />ARpesd'. GTS <br />PROJECT. 49619 U SAYE <br />olsson <br />Unite <br />orlIVIM <br />111.101•241111 =MM. <br />bmrNN**R <br />1:rM6es11�4Rt <br />PRIOR TO CONSTRUCTION: <br />CALL B11 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />MANAGE STRUCTURES HAVE <br />BEEN ROTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE. 111E1R LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. R E THE <br />RESPONSIBUTY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH COSTING UTLRY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CM <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECFICATIONS <br />AND STANDARD PUNS. <br />f .r(' * <br />a GREGORY T. <br />SEIB <br />E/ E-15150 <br />NI <br />LI7 U AAN....ePPy <br />Yt <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.