My WebLink
|
Help
|
About
|
Sign Out
Browse
202205341
LFImages
>
Deeds
>
Deeds By Year
>
2022
>
202205341
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/20/2022 4:01:13 PM
Creation date
7/20/2022 3:59:14 PM
Metadata
Fields
Template:
DEEDS
Inst Number
202205341
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY FACILITIES <br />MAY NOT BE INDICATED ON THESE PUNS. UNDERGROUND UTILITIES, <br />WHETHER SHOWN OR NOT. WILL BE LOCATED AND FLAGGED BY THE <br />UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO EXCAVATION <br />WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND UTIUTIES <br />UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND IDENTIFIED TO <br />THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND AERIAL <br />UTIUTIES AND CONSTRUCTIONS. <br />2. UNLESS OTHERWISE AGREED TO IN WRITING IN ADVANCE OF THE <br />PROJECT CONSTRUCTION, THE DEPTH OF INSTALLED FACILITIES <br />SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOIL. <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE <br />FLOW LINE OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) <br />VERTICAL SLOPE. <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM <br />THE SURFACE OF SAID ROADWAY TO THE TOP OF THE <br />INSTALLATION. <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK <br />CHANNEL DESIGN FLOW LINE, AND <br />E. MAINTAIN A MINIMUM OF 24' OF VERTICAL & HORIZONTAL <br />SPACING FROM EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL <br />REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREET PANEL WILL REQUIRE <br />FULL PANEL REPLACEMENT OR CORE REPLACEMENT WITH AN <br />APPROVED EPDXY. <br />5. ANY CUT OR POTHOLE IN AN ASPHALT STREET LANE WILL REQUIRE SEAM <br />TO SEAM ASPHALT MILLING AND REPLACEMENT. <br />B. ALL WORK ZONE TRAFFIC CONTROL, INCLUDING PEDESTRIAN CONTROL <br />MEASURES, SHALL BE IN COMPLIANCE WITH THE MUTCD, LATEST EDITION, <br />AND ADA. <br />1Y <br />76"." <br />AERIAL FIBER INSTALLATION <br />1. INSTALL THE MESSENGER WITH CABLES TO SPECIFIED SAG AS SUBMITTED <br />ON COMM -SCOPE SAG DATA. <br />2. FIELD VERIFY ALL NEWLY INSTALLED CABLE/MESSENGER CLEARANCES ARE <br />CONSTRUCTED IN ACCORDANCE WITH THE NESC. <br />3. ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />ANO PLUGGED WITH SIMILAR MATERIALS AS STATED IN THE CONTRACT. <br />4. GROUNDING TO BE INSTALLED AS STATED IN THE CONTRACT. <br />PROJECT NO. <br />SHEET N0 <br />UPN: PO -32594 <br />310: 200438.77 <br />Data: 13-JUN.2022 <br />Dram: JDH <br />Checked: MAF <br />Aeero44, Ile <br />Unite <br />ALLO COMMUNICATIONS - <br />COCA-COLA <br />1617 HOLLAND DR. <br />GRAND ISLAND, NE <br />Flow wtlat% below. <br />Call Wont youaa <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE. <br />ELECTRIC. GAS MANS. CABLE <br />TELEVISION ANO OTHER UTILITIES. <br />EXISTING (UNDERGROUND AND <br />OVERHEAD UTILITIES AND DRAINAGE <br />STRUCTURES HAVE BEEN PLOTTED <br />FROM AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS MUST <br />BE CONSIDERED APPROXIMATE ONLY. <br />ITIS THE RESPONSIBIUTY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXISTING UTILITY BEFORE AND <br />DURING ACTUAL CONSTRUCTION. <br />JEO CONSULTING GROUP INC <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.