My WebLink
|
Help
|
About
|
Sign Out
Browse
202106242
LFImages
>
Deeds
>
Deeds By Year
>
2021
>
202106242
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/23/2021 10:20:39 AM
Creation date
7/23/2021 10:08:37 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202106242
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LEGEND OF SYMBOLS <br />EXISTI140 CONDOR <br />EXISTING AERIAL FIBER <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL RBFA. OVERLASH <br />MESSENGER CABLE <br />EXISTING CONDUIT <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />EXISTING SLACK LOOP <br />EXISTING SPLICE CASE <br />EXISTING MANHOLE <br />SKIN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />ECM <br />B e Conduit Bored (e..3" B) <br />C Is concluder (ie.. 3/0) <br />CC is Coaxial Cade <br />CCC Is Camera Control Cade <br />CDC Is Camera Detector Cable <br />CG a Ckdi1 Ground <br />CPC Is Camera Power Cade <br />DB Is dreg Burled <br />DMSC Is Dynamic Message Sign Cade <br />EDC Is Emergency Detector Cade <br />ETW Is Electric Tracer Vire <br />EX Is Existing <br />R Is Fabric Iderdud <br />FLC a Fiber Locale Cabe <br />FTW a Fiber Tracer Wire <br />INS Is Instal <br />INT a Intraduct <br />LC is Lead -In Cabe <br />M Is Conduit Moulted (Ie.2- M) <br />MB is Mein Line Conduit Group Bored (6) 1 1/4' <br />MM a Mufti Mode Fiber Cade <br />MT a Main Line Conduit Group Trended (6) 1 t/4' <br />NO Is Number <br />OH Is Pier Head <br />PR Is Pak of Canmuicalbn (i..8 PR) <br />REL Is Relocate <br />REM Is Renew <br />0GS Is RI9)0 GeNanlzed Steel <br />SC Is Service Cede <br />SL is Street Light <br />SM is Singe Mode Fber Cede <br />T Is Conduit Trenched (8..3" T) <br />TW a Tracer Wire pack or green) <br />PCA243636.00006 <br />1.1.1.VMe.OXRatt1t AA`akWLV. <br />r=tie. rwwu._w <br />tOritra <br />`tueaiarowa...•. <br />944 mow Am. <br />Porbe mai Me, <br />kulne <br />.kr w.rre.. s <br />eearAllmaeuerwr <br />Inv& Dimmiors <br />I woo ow. <br />I <br />UPN PULL BOX, 24"X36"X36" <br />ore A <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT. 2" B <br />LF. <br />455 <br />TRACER WIRE <br />LF, <br />455 <br />UPN PULL BOX <br />EA <br />FIBER. 144 SM. UNDERGROUND <br />LF. <br />455 <br />FIBER 144 SM. UNDERGROUND SLACK STORAGE <br />LF. <br />160 <br />•ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES AR <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK .• <br />PROJECT NOTES <br />t. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTIUTIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION NALL BE PERMITTED N THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CRY. THE DEPTH OF <br />INSTALLED FACILITES SHALL BE. AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOIL, <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW UNE <br />OF A D0CH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE. <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW UNE. AND <br />E. MAINTAIN A MINIMUM OF 24' OF VERTICAL d HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REOUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />PROJECT N0. <br />SHEET N0. <br />017-4978 <br />G.1 <br />Dere: 07%07,2021 <br />Drawn' PTA <br />Crocked <br />APProw l: 508 GTS <br />PROJECT: 2181 CMN 23 MOVE <br />olsson <br />eems,r. <br />{�! <br />ittSt <br />rant release <br />erminew MIM <br />OsaraYf leolet <br />�til�alM� <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MANS, CABLE <br />TELEVISION AND OTHER UTIUTIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDMDUA. CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET <br />CITY OF GRAND ISLAND <br />STANDARD CONSTRUCTION <br />SPECIFICATIONS AND STANDARD <br />RAMS. <br />GENERAL NOTES <br />aND <br />FP <br />
The URL can be used to link to this page
Your browser does not support the video tag.