Laserfiche WebLink
PROJECT NOTES <br />"All work shat be performed n accordance with the Design and Construction Standards of the City and shall be <br />completed to the satisfaction of the City Engineer. h the event that a design element does not reflect City specifications, <br />the matter must immediately be brought to the attention of the design engineer and the City Engineer. The design engineer <br />shall be responsible for recommending a solution or alternative solutions to the City for review and approval" <br />'The approval of an engineering construction drawing does not relieve the owner -developer -contractor of the responsibility of <br />constructing workable public improvements. All revisions and/or corrections required will be solely the owner's -developer's - <br />contractor's responsibility, and at their expense." (b) <br />'These plans have been checked by the City only for conformance with the Design and Construction Standards, <br />compliance with development agreement conditions and for general conceptual approval of public improvements as shown. <br />No detailed mathematical check was made for the accuracy of existing or proposed dimensions, lines or grades shown, <br />including all existing utilities shown a not shown:' <br />"Utility locations shown reflect available record data. The contractor shall take precautionary measures to protect ad utility <br />lines shown and other utility lines otherwise located. The contractor shall notify the City Utilities Division and private utility <br />companies 24 hours prior to beginning construction" <br />Before work begins, the contractor shall obtain a permit to work h the right-of-way from City Engineering Support Services <br />and must notify the City right-of-way inspection staff 24 hours n advance of commencing construction activittes." <br />"The owner -developer shall provide the contractor with a complete and updated set of engineering construction drawings. <br />These drawings, and any required permits, shall be at the site at al times aid shall be make available to City staff upon <br />request. If no plans appear on the project site, construction activities may be halted at the discretion of the City Engineer, <br />or a designated representative." <br />'The contractor agrees to comply with the provisions of the ATSSA Guide for Work Area Traffic Control and the Manual of <br />Uniform Traffic Control Devices for construction signage" <br />"All surplus materials, tools, and the temporary structures, fumished by the contractor, shall be removed from the project <br />site by the contractor. All debris and rubbish caused by the operations of the contractor shall be removed, and the area <br />occupied during construction activities shall be restored to its original condition, within 72 hours of project completion, unless <br />otherwise directed by the City Engineer." <br />TELECOMMUNICATION FACILITY STANDARDS <br />The following standards shall apply to all telecommunication related facilities <br />constructed within the City's Right -of -Way including local telephone, long distance <br />telephone, cable TV, and other telecommunication services franchised or otherwise <br />permitted By the City of Grand Island. All telecommunications facilities constructed n <br />the City's Right -of -Way shall be underground unless otherwise permitted by the <br />City Engineer. <br />General <br />(a) All telecommunications facilities construction shall conform to the reqirements <br />of the following standards: <br />(1) American National Standards Institute, Inc. (ANSI), Electronic <br />Industries Association (EIA), and Telecommunications Institute of America (TIA) <br />Standards: EIA/TIA Standards Proposal No. 2840-A, Proposed Revision of EIA/TIA-568 <br />(if approved to be published as EIA/TIA-568-A), EIA/TIA-569 Commercial Building <br />Standard for Telecommunications Pathways and Spaces, and TIA/EIA-607 Commercial <br />Building Grounding and Bonding Requirements for Telecommunications. <br />(2) 1993 National Electrical Safety Code (NESC) C2-1993, published by the <br />Institute of Electrical and Electronics Engineers (IEEE), Inc. <br />(3) National Electrical Code (NEC), published by the National Fire Association <br />(NFPA). <br />(a) <br />(4) Federal Communications Commission <br />(5) Nebraska Public Utilities Commission <br />(6) Williams -Steiger Occupational Safety and Health Act (OSHA) <br />Detailed 1 incl = 30 feet scale engineering drawings presenting the specific <br />conduit routing and associated manhole locations and specifications, shall be <br />submited to the City Engineer's office for review and approval. <br />Underground Cable Protection <br />All buried telecommunications cable, shall be installed n conduit, SDR -11 <br />or equivalent. Cable placement by means of direct plow -in will not be allowed <br />within the City's Right -of -Way, <br />Depth of Cover <br />(a) Th rr.:ni um depth of cover over the conduit shall be 48 inches. <br />Trench Specifications - Roadway and Other Paved Surfaces <br />(a) All trenches shall be open cut unless otherwise permitted by the City. <br />(b) Trenches shall have a minimum width of 6 inches. <br />(c) Trench backfill shall be flowable fill specified as a 0.6 sack mix <br />Trench Specifications - Landscaped Areas <br />(a) All trenches shall be open cut unless otherwise permitted by the City. <br />(b) Trenches shall have a minimum width of 6 inches. <br />(c) Trenches shad be backfilled and compacted to at least 95 percent of maximum <br />density at optimum moisture content as determined by ASTM D698. <br />(d) The City Forester shall be contacted 10 determine if the proposed work will cause <br />any damage to trees, shrubs or other landscaping. <br />Joint Use Trench Requirements <br />(a) Joint trenching operations require advanced planning and coordination with the <br />utilities involved. <br />(b) The above trench specifications shad also apply to joint use trenches <br />LEGEND <br />-- - STREET SIGN <br />Vz FIRE HYDRANT <br />O WAIER MEIER <br />O UTILITY VALVF. <br />• UTILITY POLE <br />• UTILITY MANHOLE <br />C UTILITY HANDHOLE <br />Ill ELECTRICAL/UTILITY CABINET <br />[.I IELEPHONE PEO - CROSS BOX <br />ni PROPOSED VIAERO MANHOLE <br />PROPOSED VIAERO HANDHOLE <br />1_1 STORM INLET <br />HI STORM GRAIE <br />CULVF.RT <br />4 TREE <br />CUT -RESTORE <br />LINETYPES <br />t 1) P N <br />t+ttHttHtHtH- <br />_- ti Inti <br />CIRBUIT$ERIIInND 80 OYNERS <br />CCWDUIT-IPSOW / IRENOi1 <br />CONW0-0IRECOONA0 8060 <br />RIGIDA/-WAY <br />EDGE Of ASINAIT <br />EDGE 6 SAn\n <br />EDGE Cr LOEWAU, <br />FENCFEXISIING <br />GUPAD baus0NG <br />8006060-0050 <br />005.68STING <br />UNOEWNOONO W:CTA/C-EXISTINC <br />01.ipnomaisnric <br />STORM SEYEREXISTING <br />SANITARY SEVER -EXISTING <br />SI0,W-EXISTING <br />WAER-E8511NG <br />BUR pNG <br /><1 <br />s1war TC.Ea o 1na�meN <br />11-55) <br />VIAERO' <br />Fiber Networks, LLC <br />PN:I47D/8741X2 <br />I m. ami <br />Rim <br />BRAG BANG 11 0-1 TONER <br />LNath)FG-011-1 GGID MID ISL <br />ISLA. NEew1.SYCa <br />PROJECT NOTES <br />MS NRR: VCR <br />sat <br />11 1A <br />YSt <br />NOT 10 SCALE <br />EWE SEP <br />04 <br />r EA 01 <br />