PROJECT NOTES <br />(c) Vertical and horizontal separations between telecommunications facilities and other <br />facilities shall be maintained as required by the NESC Section 32 Underground Conduit Systems. <br />Conduit systems for telecommunications facilities shall be separated from conduit systems for <br />power supply systems by: <br />(1) 3 inches of concrete <br />(2) 4 inches of masonry <br />(3) 12 inches of well -tamped earth <br />Waming Tape <br />(a) A detectable orange colored cable waming tape shall be placed 12 to <br />18 inches move, the conduit n the bench. <br />Hand -holes <br />{a) All cavities required for cable pulling purpose shall be constructed as <br />load bearing Hand -holes. <br />(b) Hand -holes shat be placed at as specified an plans and approved by Viaero_ <br />h no case shall conduit bend radius exceed 180 degrees between structures. <br />Hand -holes shall be either a 48"x30"x24" precast composite concrete or a 24"x36"x24" <br />precast composite concrete. Refer to project detail sheet 64 for specifications. <br />Separations from Other Public Utilities and Drainage Facilities <br />(a) Parallel separations are required to satisfy standards for utility trenching <br />excavations and to provide for adequate maintenance operations. <br />(1) The minimum paraNel separation between telecommunications conduit <br />and water pipe or drainage pipe and other pipe with a depth of cover of less than <br />6 feet shall be 5 feet. <br />(2) The minimum parallel separation between telecommunications conduit <br />and wastewater pipe or other pipe with a depth of cover of more than 6 feet shah <br />be 10 feet. <br />(b) Vertical separation at utility crossings shall be as follows: <br />(1) The minimum vertical separation between telecommunications conduit <br />and City public utilities shall be 6 inches. <br />At crossings of natural and improved drainage ways, and irrigation ditches, <br />shaN meet the following conditions: <br />(1) Telecommunications conduit shall be placed a minimum 48 inches below the invert <br />of the drainage way or ditch. This minimum depth of cover shal apply whether or not the <br />drainage way 5 an open system or contained within a culvert. <br />(2) The telecommunications conduit shah be placed it a SDR -11 <br />b accomidate placed conduits. Wien the drainage way or ditch 5 at open system. the sleeve <br />shall extend a minimum horizontal distance of 10 feet beyond each side of the drainage way, measured <br />from top of bank to top of bank. <br />(3) then the drainage way or ditch s it a culvert, and the culvert openings greater <br />than 5 feet, the sleeve shall extend a minimum horizontal distance of 5 feet beyond each <br />side of the culvert, or shall extend a minimum horizontal distance equal to the vertical depth of <br />the culvert, measured from the culvert invert to the final ground surface above the culvert. <br />LEGEND <br />u STREET SIGN <br />j; FIRE HYDRANT <br />WATER METER <br />e UTILITY VALVE <br />R, UTILITY POLE <br />UTILITY MANHOLE <br />4 ELECTRICAL HH - TRAFFIC HH <br />TELEPHONE PED - TELECOM HH <br />nii PROPOSED VIAERO MANHOLE <br />c.I PROPOSED VIAERO HANDHOLE <br />0 TREE <br />i;p STORM INLET <br />UNETYPES <br />.. ... CONDanNOT N CONNAn <br />CONWN-IIRENCH / 0.WlI <br />CONOUun <br />T-aaNN. 31R[ <br />RIGIT-Or'-WAY <br />EDGE V ASPHALT <br />GASINSTING <br />ONOERGROIRO DICING -EXISTING <br />TELEPHONE-EXIST/4 <br />STIIEI SFEm-LXIS71NG <br />SANITARY SEYIEINRISTING <br />SIEAN-0OSTING <br />WATIA-EONMG <br />LOGO a WONG <br />NIO111 3 RGaTB46194 <br />VIAERO" <br />Fiber Networks, LLC <br />1124 W RAN Ah RI'.1-I10-1,1141 <br />iAl NARn CO PIR WHILNIHTGI 11 <br />S n1 <br />SCHIr.1MER DRNE <br />CITY CF GRAD MAW <br />IOC <br />PROJECT NOTES <br />IR 11m10: <br />CO DOM COMM <br />RGC NIS <br />IOW Olt BMWS <br />05 <br />NIT: R CO W <br />Elitzoozov <br />