Laserfiche WebLink
PROJECT NOTES <br />(a) "AN work shall be performed n accordance with the Design and Construction Standards of tile City and shall be <br />completed to the satisfaction of the City Engineer. h the event that a design element does not reflect City specifications, <br />the matter must Immediately be brought b the attention of the design engineer and the City Engineer. The design engineer <br />shal be responsible for recommending a solution or alternative solutions to the City for review and approval." <br />(b) 'The approval of an engineering construction drawing does not relieve the owner -developer -contractor of the responsibility of <br />constructing workable public improvements. All revisions and/or corrections required will be solely the owner's -developer's - <br />contractor's responsibility, aid at their expense.' <br />(c) 'These plans have been checked by the City only for conformance with the Design and Construction Standards, <br />compliance with development agreement conditions and for general conceptual approval of public improvements as shown. <br />Nb detailed mathematical check was made for the accuracy of existing or proposed dimensions. lines or grades shown, <br />including al existing utilities shown or not shown." <br />(d) "Utility locations shown reflect available record data. The contractor shall take precautionary measures to protect all utility <br />lines shown and other utility lines otherwise located. The contractor shall notify the City Utilities Division and private utility <br />companies 24 hours prior to beginning construction." <br />(e) Before work begins, the contractor shall obtain a permit to work n the right-of-way from City Engineering Support Services <br />and must notify the City right-of-way inspection staff 24 hours h advance of commencing construction activities" <br />"The owner -developer shah provide the contractor with a complete and updated set of engineering construction drawings. <br />These drawings, and any required permits, shall be at the site at al times and shall be make available to City staff upon <br />request. If no plans appear on the project site, construction activities may be halted at the discretion of the City Engineer, <br />or a designated representative" <br />"The contractor agrees to comply with the provisions of the ATSSA Guide for Work Area Traffic Control and the Manual of <br />Uniform Traffic Control Devices for construction signage." <br />"ATI surplus materials, tools, and the temporary structures, fumished by the contractor, shall be removed from the project <br />site by the contractor. All debris and rubbish caused by the operations of the contractor shall be removed, and the area <br />occupied during construction activities shall be restored to its original condition, within 72 hours of project completion, unless <br />otherwise directed by the City Engineer." <br />TELECOMMUNICATION FACILITY STANDARDS <br />(ii <br />(9) <br />(H) <br />The following standards shall apply to al telecommunication related facilities <br />constructed within the City's Right -of -Way including local telephone, long distance <br />telephone, cable TV, and other telecommunication services franchised or otherwise <br />permitted By the City of Kearney. Al telecommunications facilities constructed n <br />the City's Right -of -Way shall be underground unless otherwise permitted by the <br />City Engineer. <br />General <br />(a) Al telecommunications facilities construction shall conform to the reqirements <br />of the following standards: <br />(1) American National Standards Institute, Inc (ANSI), Electronic <br />Industries Association (EIA}, and Telecommunications Institute of America (TTA) <br />Standards: EIA/TIA Standards Proposal Na 2840-A, Proposed Revision of EIA/TIA-568 <br />(if approved to be published as EIA/TIA-568-A}, EIA/TIA-569 Commercial Building <br />Standard for Telecommunications Pathways and Spaces, and TIA/EIA-607 Commercial <br />Building Grounding and Bonding Requirements for Telecommunications. <br />(2) 1993 National Electrical Safety Code (NESC) C2-1993, published by the <br />Institute of Electrical and Electronics Engineers (IEEE), Inc. <br />National Electrical Code (NEC), published by the National Fire Association <br />(3) <br />(4) Federal Communications Commission <br />(5) Nebraska Public Utilities Commission <br />(6) Williams -Steiger Occupational Safety and Health Act (OSHA) <br />(b) Detailed 1 inch = 30 feet scale engineering drawings presenting the specific <br />conduit routing and associated manhole locations and specifications, shall be <br />submited to the City Engineer's office for review ad approval. <br />Underground Cable Protection <br />(a) All buried telecommunications cable, shall be installed ih conduit, SDR -11 <br />or equivalent. Cable placement by means of direct plow -in will not be allowed <br />within the City's Right -of -Way, <br />Depth of Cover <br />(a) The minimum depth of cover over the conduit shall be 48 inches. <br />Trench Specifications - Roadway and Other Paved Surfaces <br />(a) All trenches shall be open cut unless otherwise permitted by the City. <br />(b) Trenches shal have a minimum width of 6 inches. <br />(c) Trench backfill shall be flowable fill specified as a 0.6 sack mix <br />Trench Specifications - Landscaped Areas <br />(a) Al trenches shal be open cut unless otherwise permitted by the City. <br />(b) Trenches shall have a minimum width of 6 inches. <br />(c) Trenches shal be badkfiNed and compacted to at least 95 percent of maximum <br />density at optimum moisture content as determined by ASTM D698. <br />(d) The City Forester shall be contacted to determine if the proposed work will cause <br />any damage to trees, shrubs or other landscaping. <br />Joint Use Trench Requirements <br />(a) Joint trenching operations require advanced planning and coordination with the <br />utilities involved. <br />(b) The above trench specifications shall also apply to joint use trenches <br />LEGEND <br />• STREET SIGN <br />Sy FIRE HYDRANT <br />WATER MEIER <br />s UTILITY VALVt. <br />• UTILITY POLE <br />@ UTILITY MANHOLE <br />UT ELECTRICAL HN - TRAFFIC HH <br />111 IELEPHONE PED - IELECOM fH <br />ml PROPOSED VIAERO MANHOLE <br />G1 PROPOSED VIAERO HANDHOLE <br />0 TREE <br />STORM INLET <br />LINETYPES <br />--000 <br />CONDUIT -NOT N CONTRACT <br />CONDUIT.(IRENCH F PLOY) <br />CONDUIT DIREC110NAL BORE <br />RIGHT -Of -WAY <br />EDGE Cr ASPHAIJ <br />0*5010UNG <br />JNIXPGRCIJNO 0.ECSNi-EX1SUNG <br />miPNONE.EXISI:NG <br />POW, 5E\\e1-E0511ND <br />SANITARY SE\\el.EXIS111G <br />OtAM{FISTING <br />WAIEREA511NG <br /><1 <br />IIRR, W eVorro <br />mu® & Btoo <br />MM. ROFISIti 6EN <br />VIAERo• <br />Fiber Networks, LLC <br />tiio Rt147.4114142 <br />- Maw twasacml <br />IR MK* <br />SCliPAMER DRNE <br />CITY CF CRAM ISLAND <br />PROJECT NOTES <br />05 1. V 0141:1N50110R,ER• <br />DRi OWh. <br />N16 <br />KO ant 511,0,e <br />SEff <br />04 <br />S,m. 01 CI Ol <br />6FF OOgou <br />