4.2 CONCRETE REINFORCEMENT
<br />MATERIAL PROPERTIES (U.N.0)
<br />SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE 1.4.000 pal
<br />SPECIFIED YIELD STRENGTH OF CONCRETE REINFORCEMENT: f=60,000 pi
<br />A. ALL BAR LAPS SMALL CONFORM TO ACI 318 CLASS SPUCE CRITERIA. USE TO BAR LAP LENGTHS
<br />FOR TOP BARS IN SLABS MD BEAMS OVER 14. DEEP.
<br />MMMUM BAR LAPS AS FOLLOWS U.N.O.:
<br />1/3:1'-1' N4:1'-4' N5:1'-10' 116:7-T 117:4'-2'
<br />N8:5-2' N85'd' p10:73' t11:9'-0'
<br />FOR EPDXY COATED BARS, PROVIDE 1.5 TIMES THE INDICATED LAP LENGTH. FOR TOP BARS
<br />PROVIDE 1.3 TIMES THE INDICATED LAP LENGTH.
<br />B. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE MORE THAN ONE BAR
<br />MAKES UP A CONTINUOUS STRING.
<br />C. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH AG 315. ALL REINFORCEMENT BARS SHALL
<br />BE FABRICATED IN ACCORDANCE WITH THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND
<br />SHALL BE CLEAN AND FREE OF GREASE AND SCALING RUST.
<br />G.
<br />H.
<br />4.3
<br />A
<br />B.
<br />C.
<br />PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION IN ACCORDANCE WITH ACI
<br />RECOMMENDATIONS AND PROJECT SPECIFICATIONS.
<br />CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER. U.N.O.:
<br />FOOTINGS: ALL SIDES 3'
<br />PIERS: ALL SIDES 3'
<br />EXTEND ALL PIER STEEL TO PROVIDE STD. HOOK UNDER FOOTING REINFORCEMENT, UNLESS
<br />NOTED OTHERWISE.
<br />SPLICES IN REINFORCEMENT STEEL ARE PROHIBITED, UNLESS APPROVED BY THE STRUCTURAL
<br />ENGINEER ALL SPLICES MUST THEN MEET ALL APPLICABLE ASTM STANDARDS FOR SPLICING.
<br />HEATING AND WELDING OF BARS IS PROHENTED UNLESS WRITTEN APPROVAL IS OBTAINED FROM
<br />THE STRUCTURAL ENGINEER. WELDING SMALL BE IN ACCORDANCE WITH THE AMERICAN WELDING
<br />SOCIETY (AWG) D.1.1-92. STRUCTURAL WELDING CODE.
<br />CAST -IN -PLACE CONCRETE
<br />ANY NON-STRUCTURAL SITE CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000
<br />PSI. ALL CONCRETE SUBJECT TO FREEZE -THAW SHALL CONTAIN 4-8%AIR ENTRAINMENT.
<br />ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF) UNLESS NOTED OTHERWISE. ALL CONCRETE
<br />SHALL BE COMPOSED OF PORTLAND CEMENT, TYPE III, IN CONFORMANCE WITH ASTM C150, FINE
<br />AND COARSE AGGREGATE IN CONFORMANCE WITH ASTM C33, AND WATER IN CONFORMANCE WITH
<br />ASTM C94. EXPOSED EXTERIOR CONCRETE SHALL BE AIR ENTRAINED WITH % AIR CONTENT.
<br />CONCRETE SHALL HAVE A MEASURED SLUMP OF 4' (CONTRACTOR SHALL PERFORM SLUMP TESTS).
<br />IF AN ALTERNATIVE MIX DESIGN IS DESIRED, MIX DESIGN SHALL BE SUBMITTED TO ENGINEER FOR
<br />APPROVAL.
<br />•
<br />ALL CONCRETE SHALL BE VIBRATE DIN PLACE USING HIGH FREQUENCY, LOW AMPLITUDE
<br />MECHANICAL IMMERSION TYPE VIBRATORS. INSERT VIBRATORS IN CONCRETE AT REGULAR
<br />INTERVALS AND OVER ENTIRE SURFACE TO SOLIDLY FILL AROUND AND BETWEEN REINFORCEMENT
<br />AND EMBEDDED ITEMS AND INTO CORNERS AND IRREGULARITIES. DISCONTINUE ABRATION WHEN
<br />RISING ENTRAPPED NR BUBBLES STOP BREAKING THE LEVELING SURFACE. DO NOT OVERVIBRATE
<br />AS TARS MAY CAUSE SEGREGATION.
<br />ALL FORMED CONCRETE SURFACES EXPOSED TO VIEW SHALL HAVE A SURFACE FINISH SF-2.0 IN
<br />ACCORDANCE WITH ACI 301.
<br />ALL CONCRETE MIXING, TRANSPORTING. PLACING AND CURING SHALL CONFORM WITH THE LOCAL
<br />BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING STANDARDS (LATEST EDITION):
<br />'ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC..
<br />'ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT'
<br />'AG 301. SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR SLOGS."
<br />'ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK'
<br />ALUMINUM CONDUIT IS NOT PERMITTED TO BE EMBEDDED IN CONCRETE.
<br />ALL DOWELS INTO EXISTING CONCRETE OR SOLID MASONRY TO BE EPDXY AND ANCHORED WITH
<br />HILTI MT-HY 200 ADHESIVE OR APPROVED EQUIVALENT, (UNLESS NOTED OTHERWISE).
<br />H UNLESS NOTED OTHERWISE, ANY EXISTING CONCRETE SURFACE IS TO BE CLEANED AND
<br />INTENTIONALLY ROUGHED TOA 1/4' AMPLITUDE AND WETTED PRIOR TO FRESH CONCRETE BEING
<br />POURED AGAINST SURFACE.
<br />4.4 QUALITY CONTROL
<br />A. ALL STRUCTURAL CONCRETE SHALL BE INSPECTED BY INDEPENDENT, QUALIFIED PERSONNEL (ACI
<br />OR OTHERWISE), ALL STRUCTURAL CONCRETE SHALL BE TESTED BY AN INDEPENDENT LAB. AT A
<br />MINIMUM, 5 CYUNDERS SHALL BE CAST AND TESTED AT 7. 14, AND 28 DAYS. THE REMAINING
<br />CYLINDER SHALL BE RESERVED FOR RE -TESTING, IF NECESSARY.
<br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE CONSTRUCTION MANAGER
<br />AND/OR TESTING AGENCYA MINIMUM OF 48 HOURS PRIOR TO EACH FOUNDATION POUR. IF A POUR
<br />OCCURS WITHOUT THE REQUESTED INSPECTION. THE OWNER CAN ASSUME THAT THE
<br />INSTALLATION WAS NOT INSTALLED CORRECTLY AND REQUIRE REPLACEMENT.
<br />B. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REPLACE. AT THEIR SOLE EXPENSE.
<br />ANY CONCRETE THAT DOES NOT MEET THE ABOVE SPECIFICATIONS, OR SIMILAR SPECIFICATIONS
<br />CONTAINED IN THE PLANS OR STRUCTURE DRAWINGS. ANY CONCRETE THAT DOES NOT MEET THE
<br />MINIMUM COMPRESSIVE STRENGTH REQUIRED UPON COMPLETION OF LAB TESTING SHALL BE
<br />REPLACED. THE AVERAGE OF THE TWO 28 DAY BREAK RESULTS SHALL GOVERN. NO DISPUTES
<br />REGARDING THE METHOD USED TO COLLECT THE TEST CYLINDERS OR PERFORM THE LAB TESTING
<br />ARE ALLOWED. IF THE CONTRACTOR CHOOSES, THEY MAY COLLECT AND TEST ADDITIONAL
<br />CYUNDERS AT THEIR SOLE EXPENSE.
<br />C. DESPITE THE ABOVE REQUIREMENT. THE CONTRACTOR IS RESPONSIBLE TO PERFORM QUALITY
<br />WORK AND IS THE GUARANTOR OF THE FINISHED PRODUCT. IF A DEFECT IS NOT IMMEDIATELY
<br />IDENTIFIED BY THE INSPECTOR, OWNER, OR CONSTRUCTION MANAGER, BUT IDENTIFIED
<br />SUBSEQUENTLY, THE CONTRACTOR SHALL STILL BE RESPONSIBLE TO CORRECT SAID DEFECT.
<br />CONTRACTOR MUST VERIFY THAT CONCRETE MEETS DESIGN REQUIREMENT (FOR STRENGTH AND
<br />OTHER PARAMETERS) BEFORE PLACING ANY SERVICE LOADS,
<br />STRUCTURAL STEEL
<br />5.1 GENERAL REQUIREMENTS
<br />STRUCTURAL STEEL DESIGN AND FABRICATION SHALL BE IN ACCORDANCE WITH THE RISC 13TH
<br />EDITION STEEL CONSTRUCTION MANUAL.
<br />B. MATERIAL PROPERTIES ARE TO BE AS INDICATED BELOW UNLESS NOTED OTHERWISE.
<br />W SHAPES
<br />C-SHAPES 8 ANGLES
<br />PLATES 8 BARS
<br />SQUARE TUBES
<br />ROUND TUBES
<br />RODS
<br />ANCHOR RODS
<br />Fy = 38 KSI (A99) OR A 572 Gr 50)
<br />Fy = 36 KSI (A36)
<br />Fy:46 KSI (A500 Gr B)
<br />Fy = 35 KSI (A53 TYPE S. Gr B)
<br />Fy = 36 KSI (A36)
<br />Fy = 55 KSI (F1554Gr 55)
<br />C. STEEL BEAMS WITH RESIDUAL CAMBER RESULTING FROM MILL FABRICATION OR ROLLING SHALL BE
<br />SHOP FABRICATED AND ERECTED SUCH THAT THIS RESIDUAL CAMBER COUNTERACTS GRAVITY
<br />LOAD DEFLECTION.
<br />5.2
<br />CONNECTION BOLTS AND ANCHORS
<br />MINIMUM BOLT EDGE DISTANCES ARE TO BE THE LARGER OF THE EXISTING CONDITION OR THE
<br />TABLE PROVIDED BELOW UNLESS APPROVED BY THE ENGINEER.
<br />00tT DIAMETER (IN)
<br />MIN EDGE DISTANCE
<br />U2
<br />3/4
<br />7A
<br />3/4
<br />701
<br />I ER
<br />1/4
<br />1 HI
<br />I I/2
<br />1 1N
<br />15/3
<br />all/4
<br />125xA
<br />ALL CONNECTION BOLTING IS TO BE WITH A325N BOLTS UNLESS NOTED OTHERWISE BOLTS NEED
<br />ONLY BE TIGHTENED TO THE SNUG -TIGHT CONDITION. SNUG -TIGHT IS DEFINED AS THE TIGHTNESS
<br />OBTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT Of A PERSON USING AN
<br />ORDINARY SPUD WRENCH
<br />C. U.N.O.. POST INSTALLED ANCHORS ARE TO BE HILTI HIT HY 200 ADHESIVE ANCHORS FOR SOUD BASE
<br />MATERIAL AS MANUFACTURED BY HILTI FASTENING SYSTEMS OF TULSA, OKLAHOMA OR APPROVED
<br />EQUAL INSTALL ANCHORS WITH EMBEDMENT DEPTHS INDICATED.
<br />5.3 GROUT 8 FINISHES
<br />A U.N.O., NON -SHRINK GROUT SHALL BE A NON-METALLIC PREMIXED FORMULATION EQUIVALENT TO
<br />MASTERFLOW 713 PLUS BY DEGUSSA BUILDING SYSTEMS. BEAM AND LINTEL PLATES SHALL BE FULLY
<br />GROUTED WITH A MINIMUM 1V2' NON -SHRINK GROUT. COLUMN BASE PLATES SHALL BE FULLY
<br />GROUTED WITH A MINIMUM OF 1 1/Y NON -SHRINK GROUT.
<br />B. ALL STEEL FRAMING MEMBERS. CONNECTION PLATES, FASTENERS AND ANCHOR BOLTS EXPOSED TO
<br />EARTH OR WEATHER TO HAVE HOT -DIP GALVANIZED FINISH UNLESS OTHERWISE SPECIFIED. APPLY
<br />COATING BY THE HOT -DIP PROCESS FOR GALVANIZING ACCORDING TO ASTM A123 OR ASTM A153.
<br />C. ALL DINGS. SCRAPES. MARS AND WELDS IN THE GALVANIZED AREA SHALL BE COATED WITH A
<br />ZINC -RICH PAINT, APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND
<br />RECOMMENDATIONS. AFTER ZINC -RICH PAINT IS DRY, OVERCOAT WITH AN APPROPRIATE PAINT WITH
<br />THE SAME COLOR AS THE EXISTING.
<br />5A WELDING
<br />A. ALL WELDING OF NEW STEEL IS TO BE WITH E70XX ELECTRODES, U.N.O. WELDING SHALL BE IN
<br />ACCORDANCE WITH THE LATEST /MS SPECIFICATIONS BY CERTIFIED WELDERS AND INSPECTED BY
<br />AN ATVS CERTIFIED WELDING INSPECTOR.
<br />B. WHEN FIELD WELDING TO EXISTING STEEL ADJUST WELDING PROCEDURES AS REQUIRED TO BE
<br />COMPATIBLE WITH THE NEW AND EXISTING STEEL
<br />C. ALL WELDING OF GALVANIZED MATERIAL SHALL BE PERFORMED IN SUCH A MANOR AS TO SATISFY
<br />ALL OSHAAND AWS REQUIREMENTS. ALL FIELD WELDED LOCATIONS SHALL BE PREPARED AND
<br />PRIMED WITH AZINC-RICH PRIMER PRIOR TO PAINTING PER THE MANUFACTURERS
<br />RECOMMENDATIONS. THE SPECIFIC PRIMER TO BE USED SHALL BE TNEMEC SERIES 90-97 Trwns-Z/nc
<br />I¢/ 3.0-4.0 n8s OFT OR APPROVED EQUAL.
<br />ELECTRICAL
<br />A. THE CONTRACTOR SHALL LOCATE AND MARK ALL EXISTING UNDERGROUND POWER. TELCO,
<br />GROUNDING CONDUITS, AND ALL OTHER UTILITY EASEMENTS AND/OR WIRES PRIOR TO TRENCHING.
<br />ANY DAMAGE CAUSE TO THE EXISTING UNDERGROUND SERVICES OR SYSTEMS SHALL BE REPAIRED
<br />AT THE CONTRACTOR'S SOLE EXPENSE.
<br />B.
<br />C.
<br />E.
<br />CONTRACTOR SHALL CONTACT UTBITY PROVIDER PRIOR TO BIDDING AND CONSTRUCTION TO
<br />VERIFY THAT SERVICE HAS BEEN ORDERED AND DISCUSS ANY SITE SPECIFIC REQUIREMENTS.
<br />CHANGE ORDERS RELATED TO UTILITY REQUIREMENTS OR REQUESTS WALL NOT BE ALLOWED
<br />UNLESS THS CONDITION HAS BEEN MET.
<br />CONTRACTOR TO COORDINATE WITH UTIUTY COMPANY FOR CONNECTION OF TEMPORARY AND
<br />PERMANENT POWER TO THE SITE, THE TEMPORARY POWER AND ALL HOOKUP COSTS SHALL BE PAID
<br />BY CONTRACTOR.
<br />SUBMITTAL OF BID INDICATES CONTRACTOR IS AWARE OF ALL JOB SITE CONDITIONS AND WORN TO
<br />BE PERFORMED UNDER THIS CONTRACT.
<br />CONTRACTOR SHALL PERFORM ALL VERIFICATION OBSERVATION TESTS, AND EXAMINE WORK PRIOR
<br />TO THE ORDERING OF THE ELECTRICAL EQUIPMENT AND THE ACTUAL CONSTRUCTION. CONTRACTOR
<br />SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ENGINEER LISTING ALL MALFUNCTIONS,
<br />FAULT EQUIPMENT, AND DISCREPANCIES.
<br />THESE PLANS ARE DIAGRAMMATIC ONLY. FOLLOW AS CLOSELY AS POSSIBLE
<br />ALL BROCHURES. OPERATING MANUALS, CATALOGS, SHOP DRAWINGS. ETC. SHALL BE TURNED OVER
<br />TO OWNER AT JOB COMPLETION.
<br />H. CONTRACTOR SHALL PROVIDE, LABOR, MATERIALS. INSURANCE, EQUIPMENT, INSTALLATION.
<br />CONSTRUCTION TOOLS, TRANSPORTATION, ETC., FORA COMPLETE AND PROPERLY OPERATIVE
<br />SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN, AND/OR
<br />AS OTHERWISE REQUIRED.
<br />I. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB
<br />ACCEPTANCE BY OWNER ANY WORK. MATERIAL. OR EQUIPMENT FOUND TO SE FAULTY DURING THAT
<br />PERIOD SHALL BE CORRECTED AT ONCE. UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE
<br />CONTRACTOR.
<br />J. UPON COMPLETION OF WORK. CONDUIT CONTINUITY, SHORT CIRCUIT. AND FALL POTENTIAL
<br />GROUNDING TESTS ARE REQUIRE FOR APPROVAL. SUBMIT TEST REPORTS TO CONSTRUCTION
<br />ENGINEER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK INA
<br />COMPLETE AND UNDAMAGED CONDITION.
<br />PROVIDE 2 PULL STRINGS SECURELY FASTENED AT EACH END OF ALL CONDUITS. ALL CONDUIT ONLY
<br />(C.O.) SHALL HAVE A PULL WIRE OR ROPE
<br />L. ALL MATERIALS UTIUZED SHALL BE U.L. USTED. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED
<br />WITH PERMANENT ENGRAVED PLASTIC LABELS.
<br />M. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANEL BOARD,
<br />PULLBOX, .-BOX. SWITCH BOX ETC. IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ACT
<br />(O.S.HA.)
<br />ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND
<br />SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS
<br />OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY THE UNDERWRITER'S
<br />LABORATORY AND SHALL BEAR THE INSPECTION LABEL -J' WHERE SUBJECT TO SUCH APPROVAL
<br />MATERIALS SHALL MEET WITH APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL
<br />GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE
<br />WITH APPLICABLE STANDARDS ESTABUSHED BY ASNI. NEMA, AND NBFU.
<br />USE T-TAP CONNECTIONS ON ALL MULTI -CIRCUITS WITH COMMON NEUTRAL CONDUCTOR
<br />P. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING
<br />NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED, AND A
<br />MINIMUM OF 10,000 A.I.C.
<br />O. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALLAPPUCABLE
<br />CODES AND DRAWINGS. GROUND RODS SHALL BE AS SPECIFIED ON THE GROUNDING DRAWINGS.
<br />WIRE AND CABLE CONDUCTORS SHALL BE COPPER N12 AWG MINIMUM, NO BX OR ROMEX CABLE IS
<br />PERMITTED UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS.
<br />5. METER SOCKET AMPERAGEVOLTAGE, AND NUMBER OF PHASES SHALL RE AS NOTED ON THE
<br />DRAWINGS. MANUFACTURED BY SQUARED COMPANY OR APPROVED EQUAL. IF HOST FACILITY
<br />REQUIRES THE NEW SERVICE TO BE SUB -METERED FROM THE EXISTING SERVICE, SUB -METER SHALL
<br />BE OF THE 10x OR 16x TYPE.
<br />PATCH, REPAIR, AND PLANT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE
<br />ELECTRICAL WORK
<br />U. SERVICE CONDUITS SHALL BE GRAY SCH.40 PVC BURIED MIN. 36', EXCEPT THE SCR80 SHALL BE
<br />USED UNDER ROADWAYS AND IN LOCATIONS SUBJECT TO CASUAL IMPACTS. BENDS SHALL BE MADE
<br />USING'WIDE SWEEP" (12' MN. RADIUS) ELBOW FITTINGS. ANY CODE -REQUIRED RIGID STEEL
<br />CONDUIT SHALL BE U.L LABEL GALVANIZED INSIDE AND OUTSIDE. CONDUIT SHALL EXTEND MN. 36'
<br />BELOW GRADE WITH 'SWEEP ELBOWS (IT MIN. RADIUS) ENDING IN PVC TRANSITION FITTINGS. RIGID
<br />CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAB -WRAPPED WITH HUNTS PROCESS NO. 3
<br />EXTENDING MIN. ABOVE GRADE.
<br />V. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING HAVING U.L. LABEL FITTINGS SHALL BE
<br />GLAND RING COMPRESSION TYPE
<br />W, FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE PERMITTED
<br />BY CODE. FITTING SHALL BE 'JAKE' OR 'SQUEEZE' TYPE, SEAL TIGHT FLEXIBLE CONDUIT. NO SUCH
<br />CONDUIT SHALL EXCEED SIX FEET IN LENGTH.
<br />POLE AND ANTENNA INSTALLATION
<br />A. IF REQUIRED, ERECT FURNISHED STRUCTURE. PRIOR TO ERECTION, CONTRACTOR MUST VERIFY
<br />THAT CONCRETE HAS MET THE MINIMUM STRENGTH REQUIREMENTS AS WELL AS ANY OTHER
<br />INSPECTION OR TESTING REQUIREMENTS.
<br />B. INSTALL ANTENNAS AND UNES AS INDICATED ON THE DRAWINGS AND PER OWNER SPECIFICATION.
<br />INSTALL ANTENNA AND CABLE MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS OR
<br />APPROVED BY THE CONSTRUCTION MANAGER ANTENNA INSTALLATION TO BE CONDUCTED BY FIELD
<br />CREWS EXPERIENCED IN THE ASSEMBLE AND ERECTION OF ANTENNAS. TRANSMISSION LINES AND
<br />SUPPORT STRUCTURE.
<br />C. ASSIST OWNER TECHNICIANS IN PERFORMING SWEEP TEST OF INSTALLED COAX.
<br />D. CONTRACTOR SHALL FOLLOW ALLAPPUCABLE STANDARDS INCLUDING, BUT NOT LIMITED TO: EIA 712
<br />(LATEST VERSION). FAA ADVISORY CIRCULAR AC70/7480-IA, FCC RULES 8 REGULATIONS
<br />LANDSCAPING & SITE RESTORATION.
<br />CONTRACTOR SHALL FURNISH. INSTALL, AND MAINTAIN LANDSCAPE WORK AS SHOWN ON THE
<br />CONSTRUCTION DRAWINGS OR REQUIRED IN THE SPECIFICATIONS.
<br />CONTRACTOR SHALL UTIUZE THE SERVICES OF ALANDSCAPE CONTRACTOR TO ENSURE THE
<br />LANDSCAPING IS PROPERLY INSTALLED, WATERED. AND OTHERWISE MAINTAINED. CONTRACTOR
<br />SHALL GUARANTEE LANDSCAPING FORA MINIMUM OF ONE (1) YEAR AND SHALL REPLACE ANY DEAD
<br />OR VISIBLY DISTRESSED PLANTS WITHIN THIS PERIOD.
<br />A. CONTRACTOR SHALL PROTECT SEEDED AREAS FROM EROSION THROUGH THE USE OF AN FRI SION
<br />CONTROL MESH OR MULCH NET.
<br />ALLTREES PLACED IN CONJUNCTION WITH A LANDSCAPE PLAN WILL BE WRAPPED. TIED WITH HOSE
<br />PROTECTED WIRE, AND SECURE TO A STEEL ANGLE EXTENDING TWO FEET INTO THE GROUND ON
<br />FOUR SIDES OF THE TREE.
<br />C. ALLEXPOSED AREAS SHALL BE PROTECTED AGAINST WASHOUTS AND SOIL EROSION.
<br />D. SEED AND FERTILIZER SHALL BE APPLIED TO SURFACE CONDITIONS TO ENCOURAGE ROOTING. RAKE
<br />AREAS TO BE SEED TO EVEN THE SURFACE AND LOOSEN THE SOIL. SOW SEED IN TWO DIRECTIONS IN
<br />TWICE THE QUANTITY RECOMMENDED BY THE SEED PRODUCER.
<br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROWTH OF SEEDED AND LANDSCAPED
<br />AREAS BY WATERING. CONTINUE TO REWORK BARE AREAS UNTIL COMPLETE COVERAGE IS
<br />OBTAINED.
<br />CONSULTANT
<br />Edge
<br />fie. IRA
<br />6.64.1.9 VOICE
<br />verizon
<br />ENGINEER SEAL
<br />I SEREST CERT, TEAT TINS PLAN
<br />SET WAS PREPARED BY ME CR
<br />NOTED IN THE SHEET POE% AND
<br />FISOFESSIONA ENGINEER
<br />UNDER THE LSWS CP ITN
<br />STATE OF NEBRISEAL
<br />EROJCO7 NO
<br />ISAOSSES
<br />LOCAL,. COOL
<br />REDS DATE
<br />OZONESIS
<br />STRLICSURA ANALYSIS:
<br />CATE
<br />AVE 1325
<br />REPORT NO 913/.71
<br />DESCRIPTION:
<br />05/22,6
<br />PER
<br />S17106
<br />Eoo
<br />42006
<br />SET
<br />TYPE
<br />FINAL
<br />6
<br />SHEET
<br />NUMBER
<br />R-002