Laserfiche WebLink
4.2 CONCRETE REINFORCEMENT <br />MATERIAL PROPERTIES (U.N.0) <br />SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE 1.4.000 pal <br />SPECIFIED YIELD STRENGTH OF CONCRETE REINFORCEMENT: f=60,000 pi <br />A. ALL BAR LAPS SMALL CONFORM TO ACI 318 CLASS SPUCE CRITERIA. USE TO BAR LAP LENGTHS <br />FOR TOP BARS IN SLABS MD BEAMS OVER 14. DEEP. <br />MMMUM BAR LAPS AS FOLLOWS U.N.O.: <br />1/3:1'-1' N4:1'-4' N5:1'-10' 116:7-T 117:4'-2' <br />N8:5-2' N85'd' p10:73' t11:9'-0' <br />FOR EPDXY COATED BARS, PROVIDE 1.5 TIMES THE INDICATED LAP LENGTH. FOR TOP BARS <br />PROVIDE 1.3 TIMES THE INDICATED LAP LENGTH. <br />B. LAP LENGTH SHALL BE SPECIFICALLY NOTED ON SHOP DRAWINGS WHERE MORE THAN ONE BAR <br />MAKES UP A CONTINUOUS STRING. <br />C. REINFORCING STEEL SHALL BE IN ACCORDANCE WITH AG 315. ALL REINFORCEMENT BARS SHALL <br />BE FABRICATED IN ACCORDANCE WITH THE LATEST CRSI MANUAL OF STANDARD PRACTICE AND <br />SHALL BE CLEAN AND FREE OF GREASE AND SCALING RUST. <br />G. <br />H. <br />4.3 <br />A <br />B. <br />C. <br />PROVIDE HOT/COLD WEATHER PROCEDURES AND PROTECTION IN ACCORDANCE WITH ACI <br />RECOMMENDATIONS AND PROJECT SPECIFICATIONS. <br />CONCRETE REINFORCEMENT PROTECTION/CLEAR COVER. U.N.O.: <br />FOOTINGS: ALL SIDES 3' <br />PIERS: ALL SIDES 3' <br />EXTEND ALL PIER STEEL TO PROVIDE STD. HOOK UNDER FOOTING REINFORCEMENT, UNLESS <br />NOTED OTHERWISE. <br />SPLICES IN REINFORCEMENT STEEL ARE PROHIBITED, UNLESS APPROVED BY THE STRUCTURAL <br />ENGINEER ALL SPLICES MUST THEN MEET ALL APPLICABLE ASTM STANDARDS FOR SPLICING. <br />HEATING AND WELDING OF BARS IS PROHENTED UNLESS WRITTEN APPROVAL IS OBTAINED FROM <br />THE STRUCTURAL ENGINEER. WELDING SMALL BE IN ACCORDANCE WITH THE AMERICAN WELDING <br />SOCIETY (AWG) D.1.1-92. STRUCTURAL WELDING CODE. <br />CAST -IN -PLACE CONCRETE <br />ANY NON-STRUCTURAL SITE CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 <br />PSI. ALL CONCRETE SUBJECT TO FREEZE -THAW SHALL CONTAIN 4-8%AIR ENTRAINMENT. <br />ALL CONCRETE SHALL BE NORMAL WEIGHT (145 PCF) UNLESS NOTED OTHERWISE. ALL CONCRETE <br />SHALL BE COMPOSED OF PORTLAND CEMENT, TYPE III, IN CONFORMANCE WITH ASTM C150, FINE <br />AND COARSE AGGREGATE IN CONFORMANCE WITH ASTM C33, AND WATER IN CONFORMANCE WITH <br />ASTM C94. EXPOSED EXTERIOR CONCRETE SHALL BE AIR ENTRAINED WITH % AIR CONTENT. <br />CONCRETE SHALL HAVE A MEASURED SLUMP OF 4' (CONTRACTOR SHALL PERFORM SLUMP TESTS). <br />IF AN ALTERNATIVE MIX DESIGN IS DESIRED, MIX DESIGN SHALL BE SUBMITTED TO ENGINEER FOR <br />APPROVAL. <br />• <br />ALL CONCRETE SHALL BE VIBRATE DIN PLACE USING HIGH FREQUENCY, LOW AMPLITUDE <br />MECHANICAL IMMERSION TYPE VIBRATORS. INSERT VIBRATORS IN CONCRETE AT REGULAR <br />INTERVALS AND OVER ENTIRE SURFACE TO SOLIDLY FILL AROUND AND BETWEEN REINFORCEMENT <br />AND EMBEDDED ITEMS AND INTO CORNERS AND IRREGULARITIES. DISCONTINUE ABRATION WHEN <br />RISING ENTRAPPED NR BUBBLES STOP BREAKING THE LEVELING SURFACE. DO NOT OVERVIBRATE <br />AS TARS MAY CAUSE SEGREGATION. <br />ALL FORMED CONCRETE SURFACES EXPOSED TO VIEW SHALL HAVE A SURFACE FINISH SF-2.0 IN <br />ACCORDANCE WITH ACI 301. <br />ALL CONCRETE MIXING, TRANSPORTING. PLACING AND CURING SHALL CONFORM WITH THE LOCAL <br />BUILDING CODE REQUIREMENTS AND THOSE OF THE FOLLOWING STANDARDS (LATEST EDITION): <br />'ACI 318, BUILDING CODE REQUIREMENTS FOR REINFORCED CONC.. <br />'ACI 315, DETAILS AND DETAILING OF CONCRETE REINFORCEMENT' <br />'AG 301. SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR SLOGS." <br />'ACI 307, RECOMMENDED PRACTICE FOR CONCRETE FORM WORK' <br />ALUMINUM CONDUIT IS NOT PERMITTED TO BE EMBEDDED IN CONCRETE. <br />ALL DOWELS INTO EXISTING CONCRETE OR SOLID MASONRY TO BE EPDXY AND ANCHORED WITH <br />HILTI MT-HY 200 ADHESIVE OR APPROVED EQUIVALENT, (UNLESS NOTED OTHERWISE). <br />H UNLESS NOTED OTHERWISE, ANY EXISTING CONCRETE SURFACE IS TO BE CLEANED AND <br />INTENTIONALLY ROUGHED TOA 1/4' AMPLITUDE AND WETTED PRIOR TO FRESH CONCRETE BEING <br />POURED AGAINST SURFACE. <br />4.4 QUALITY CONTROL <br />A. ALL STRUCTURAL CONCRETE SHALL BE INSPECTED BY INDEPENDENT, QUALIFIED PERSONNEL (ACI <br />OR OTHERWISE), ALL STRUCTURAL CONCRETE SHALL BE TESTED BY AN INDEPENDENT LAB. AT A <br />MINIMUM, 5 CYUNDERS SHALL BE CAST AND TESTED AT 7. 14, AND 28 DAYS. THE REMAINING <br />CYLINDER SHALL BE RESERVED FOR RE -TESTING, IF NECESSARY. <br />THE CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH THE CONSTRUCTION MANAGER <br />AND/OR TESTING AGENCYA MINIMUM OF 48 HOURS PRIOR TO EACH FOUNDATION POUR. IF A POUR <br />OCCURS WITHOUT THE REQUESTED INSPECTION. THE OWNER CAN ASSUME THAT THE <br />INSTALLATION WAS NOT INSTALLED CORRECTLY AND REQUIRE REPLACEMENT. <br />B. THE CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE AND REPLACE. AT THEIR SOLE EXPENSE. <br />ANY CONCRETE THAT DOES NOT MEET THE ABOVE SPECIFICATIONS, OR SIMILAR SPECIFICATIONS <br />CONTAINED IN THE PLANS OR STRUCTURE DRAWINGS. ANY CONCRETE THAT DOES NOT MEET THE <br />MINIMUM COMPRESSIVE STRENGTH REQUIRED UPON COMPLETION OF LAB TESTING SHALL BE <br />REPLACED. THE AVERAGE OF THE TWO 28 DAY BREAK RESULTS SHALL GOVERN. NO DISPUTES <br />REGARDING THE METHOD USED TO COLLECT THE TEST CYLINDERS OR PERFORM THE LAB TESTING <br />ARE ALLOWED. IF THE CONTRACTOR CHOOSES, THEY MAY COLLECT AND TEST ADDITIONAL <br />CYUNDERS AT THEIR SOLE EXPENSE. <br />C. DESPITE THE ABOVE REQUIREMENT. THE CONTRACTOR IS RESPONSIBLE TO PERFORM QUALITY <br />WORK AND IS THE GUARANTOR OF THE FINISHED PRODUCT. IF A DEFECT IS NOT IMMEDIATELY <br />IDENTIFIED BY THE INSPECTOR, OWNER, OR CONSTRUCTION MANAGER, BUT IDENTIFIED <br />SUBSEQUENTLY, THE CONTRACTOR SHALL STILL BE RESPONSIBLE TO CORRECT SAID DEFECT. <br />CONTRACTOR MUST VERIFY THAT CONCRETE MEETS DESIGN REQUIREMENT (FOR STRENGTH AND <br />OTHER PARAMETERS) BEFORE PLACING ANY SERVICE LOADS, <br />STRUCTURAL STEEL <br />5.1 GENERAL REQUIREMENTS <br />STRUCTURAL STEEL DESIGN AND FABRICATION SHALL BE IN ACCORDANCE WITH THE RISC 13TH <br />EDITION STEEL CONSTRUCTION MANUAL. <br />B. MATERIAL PROPERTIES ARE TO BE AS INDICATED BELOW UNLESS NOTED OTHERWISE. <br />W SHAPES <br />C-SHAPES 8 ANGLES <br />PLATES 8 BARS <br />SQUARE TUBES <br />ROUND TUBES <br />RODS <br />ANCHOR RODS <br />Fy = 38 KSI (A99) OR A 572 Gr 50) <br />Fy = 36 KSI (A36) <br />Fy:46 KSI (A500 Gr B) <br />Fy = 35 KSI (A53 TYPE S. Gr B) <br />Fy = 36 KSI (A36) <br />Fy = 55 KSI (F1554Gr 55) <br />C. STEEL BEAMS WITH RESIDUAL CAMBER RESULTING FROM MILL FABRICATION OR ROLLING SHALL BE <br />SHOP FABRICATED AND ERECTED SUCH THAT THIS RESIDUAL CAMBER COUNTERACTS GRAVITY <br />LOAD DEFLECTION. <br />5.2 <br />CONNECTION BOLTS AND ANCHORS <br />MINIMUM BOLT EDGE DISTANCES ARE TO BE THE LARGER OF THE EXISTING CONDITION OR THE <br />TABLE PROVIDED BELOW UNLESS APPROVED BY THE ENGINEER. <br />00tT DIAMETER (IN) <br />MIN EDGE DISTANCE <br />U2 <br />3/4 <br />7A <br />3/4 <br />701 <br />I ER <br />1/4 <br />1 HI <br />I I/2 <br />1 1N <br />15/3 <br />all/4 <br />125xA <br />ALL CONNECTION BOLTING IS TO BE WITH A325N BOLTS UNLESS NOTED OTHERWISE BOLTS NEED <br />ONLY BE TIGHTENED TO THE SNUG -TIGHT CONDITION. SNUG -TIGHT IS DEFINED AS THE TIGHTNESS <br />OBTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT Of A PERSON USING AN <br />ORDINARY SPUD WRENCH <br />C. U.N.O.. POST INSTALLED ANCHORS ARE TO BE HILTI HIT HY 200 ADHESIVE ANCHORS FOR SOUD BASE <br />MATERIAL AS MANUFACTURED BY HILTI FASTENING SYSTEMS OF TULSA, OKLAHOMA OR APPROVED <br />EQUAL INSTALL ANCHORS WITH EMBEDMENT DEPTHS INDICATED. <br />5.3 GROUT 8 FINISHES <br />A U.N.O., NON -SHRINK GROUT SHALL BE A NON-METALLIC PREMIXED FORMULATION EQUIVALENT TO <br />MASTERFLOW 713 PLUS BY DEGUSSA BUILDING SYSTEMS. BEAM AND LINTEL PLATES SHALL BE FULLY <br />GROUTED WITH A MINIMUM 1V2' NON -SHRINK GROUT. COLUMN BASE PLATES SHALL BE FULLY <br />GROUTED WITH A MINIMUM OF 1 1/Y NON -SHRINK GROUT. <br />B. ALL STEEL FRAMING MEMBERS. CONNECTION PLATES, FASTENERS AND ANCHOR BOLTS EXPOSED TO <br />EARTH OR WEATHER TO HAVE HOT -DIP GALVANIZED FINISH UNLESS OTHERWISE SPECIFIED. APPLY <br />COATING BY THE HOT -DIP PROCESS FOR GALVANIZING ACCORDING TO ASTM A123 OR ASTM A153. <br />C. ALL DINGS. SCRAPES. MARS AND WELDS IN THE GALVANIZED AREA SHALL BE COATED WITH A <br />ZINC -RICH PAINT, APPLIED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND <br />RECOMMENDATIONS. AFTER ZINC -RICH PAINT IS DRY, OVERCOAT WITH AN APPROPRIATE PAINT WITH <br />THE SAME COLOR AS THE EXISTING. <br />5A WELDING <br />A. ALL WELDING OF NEW STEEL IS TO BE WITH E70XX ELECTRODES, U.N.O. WELDING SHALL BE IN <br />ACCORDANCE WITH THE LATEST /MS SPECIFICATIONS BY CERTIFIED WELDERS AND INSPECTED BY <br />AN ATVS CERTIFIED WELDING INSPECTOR. <br />B. WHEN FIELD WELDING TO EXISTING STEEL ADJUST WELDING PROCEDURES AS REQUIRED TO BE <br />COMPATIBLE WITH THE NEW AND EXISTING STEEL <br />C. ALL WELDING OF GALVANIZED MATERIAL SHALL BE PERFORMED IN SUCH A MANOR AS TO SATISFY <br />ALL OSHAAND AWS REQUIREMENTS. ALL FIELD WELDED LOCATIONS SHALL BE PREPARED AND <br />PRIMED WITH AZINC-RICH PRIMER PRIOR TO PAINTING PER THE MANUFACTURERS <br />RECOMMENDATIONS. THE SPECIFIC PRIMER TO BE USED SHALL BE TNEMEC SERIES 90-97 Trwns-Z/nc <br />I¢/ 3.0-4.0 n8s OFT OR APPROVED EQUAL. <br />ELECTRICAL <br />A. THE CONTRACTOR SHALL LOCATE AND MARK ALL EXISTING UNDERGROUND POWER. TELCO, <br />GROUNDING CONDUITS, AND ALL OTHER UTILITY EASEMENTS AND/OR WIRES PRIOR TO TRENCHING. <br />ANY DAMAGE CAUSE TO THE EXISTING UNDERGROUND SERVICES OR SYSTEMS SHALL BE REPAIRED <br />AT THE CONTRACTOR'S SOLE EXPENSE. <br />B. <br />C. <br />E. <br />CONTRACTOR SHALL CONTACT UTBITY PROVIDER PRIOR TO BIDDING AND CONSTRUCTION TO <br />VERIFY THAT SERVICE HAS BEEN ORDERED AND DISCUSS ANY SITE SPECIFIC REQUIREMENTS. <br />CHANGE ORDERS RELATED TO UTILITY REQUIREMENTS OR REQUESTS WALL NOT BE ALLOWED <br />UNLESS THS CONDITION HAS BEEN MET. <br />CONTRACTOR TO COORDINATE WITH UTIUTY COMPANY FOR CONNECTION OF TEMPORARY AND <br />PERMANENT POWER TO THE SITE, THE TEMPORARY POWER AND ALL HOOKUP COSTS SHALL BE PAID <br />BY CONTRACTOR. <br />SUBMITTAL OF BID INDICATES CONTRACTOR IS AWARE OF ALL JOB SITE CONDITIONS AND WORN TO <br />BE PERFORMED UNDER THIS CONTRACT. <br />CONTRACTOR SHALL PERFORM ALL VERIFICATION OBSERVATION TESTS, AND EXAMINE WORK PRIOR <br />TO THE ORDERING OF THE ELECTRICAL EQUIPMENT AND THE ACTUAL CONSTRUCTION. CONTRACTOR <br />SHALL ISSUE A WRITTEN NOTICE OF ALL FINDINGS TO THE ENGINEER LISTING ALL MALFUNCTIONS, <br />FAULT EQUIPMENT, AND DISCREPANCIES. <br />THESE PLANS ARE DIAGRAMMATIC ONLY. FOLLOW AS CLOSELY AS POSSIBLE <br />ALL BROCHURES. OPERATING MANUALS, CATALOGS, SHOP DRAWINGS. ETC. SHALL BE TURNED OVER <br />TO OWNER AT JOB COMPLETION. <br />H. CONTRACTOR SHALL PROVIDE, LABOR, MATERIALS. INSURANCE, EQUIPMENT, INSTALLATION. <br />CONSTRUCTION TOOLS, TRANSPORTATION, ETC., FORA COMPLETE AND PROPERLY OPERATIVE <br />SYSTEM ENERGIZED THROUGHOUT AND AS INDICATED ON DRAWINGS, AS SPECIFIED HEREIN, AND/OR <br />AS OTHERWISE REQUIRED. <br />I. COMPLETE JOB SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR AFTER THE DATE OF JOB <br />ACCEPTANCE BY OWNER ANY WORK. MATERIAL. OR EQUIPMENT FOUND TO SE FAULTY DURING THAT <br />PERIOD SHALL BE CORRECTED AT ONCE. UPON WRITTEN NOTIFICATION, AT THE EXPENSE OF THE <br />CONTRACTOR. <br />J. UPON COMPLETION OF WORK. CONDUIT CONTINUITY, SHORT CIRCUIT. AND FALL POTENTIAL <br />GROUNDING TESTS ARE REQUIRE FOR APPROVAL. SUBMIT TEST REPORTS TO CONSTRUCTION <br />ENGINEER. CLEAN PREMISES OF ALL DEBRIS RESULTING FROM WORK AND LEAVE WORK INA <br />COMPLETE AND UNDAMAGED CONDITION. <br />PROVIDE 2 PULL STRINGS SECURELY FASTENED AT EACH END OF ALL CONDUITS. ALL CONDUIT ONLY <br />(C.O.) SHALL HAVE A PULL WIRE OR ROPE <br />L. ALL MATERIALS UTIUZED SHALL BE U.L. USTED. ALL ELECTRICAL EQUIPMENT SHALL BE LABELED <br />WITH PERMANENT ENGRAVED PLASTIC LABELS. <br />M. EACH CONDUCTOR OF EVERY SYSTEM SHALL BE PERMANENTLY TAGGED IN EACH PANEL BOARD, <br />PULLBOX, .-BOX. SWITCH BOX ETC. IN COMPLIANCE WITH OCCUPATIONAL SAFETY AND HEALTH ACT <br />(O.S.HA.) <br />ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED AND <br />SHALL BE OF THE BEST GRADE AND OF THE SAME MANUFACTURER THROUGHOUT FOR EACH CLASS <br />OR GROUP OF EQUIPMENT. MATERIALS SHALL BE LISTED AND APPROVED BY THE UNDERWRITER'S <br />LABORATORY AND SHALL BEAR THE INSPECTION LABEL -J' WHERE SUBJECT TO SUCH APPROVAL <br />MATERIALS SHALL MEET WITH APPROVAL OF THE DIVISION OF INDUSTRIAL SAFETY AND ALL <br />GOVERNING BODIES HAVING JURISDICTION. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE <br />WITH APPLICABLE STANDARDS ESTABUSHED BY ASNI. NEMA, AND NBFU. <br />USE T-TAP CONNECTIONS ON ALL MULTI -CIRCUITS WITH COMMON NEUTRAL CONDUCTOR <br />P. ALL CIRCUIT BREAKERS, FUSES AND ELECTRICAL EQUIPMENT SHALL HAVE AN INTERRUPTING RATING <br />NOT LESS THAN THE MAXIMUM SHORT CIRCUIT CURRENT TO WHICH THEY MAY BE SUBJECTED, AND A <br />MINIMUM OF 10,000 A.I.C. <br />O. THE ENTIRE ELECTRICAL INSTALLATION SHALL BE GROUNDED AS REQUIRED BY ALLAPPUCABLE <br />CODES AND DRAWINGS. GROUND RODS SHALL BE AS SPECIFIED ON THE GROUNDING DRAWINGS. <br />WIRE AND CABLE CONDUCTORS SHALL BE COPPER N12 AWG MINIMUM, NO BX OR ROMEX CABLE IS <br />PERMITTED UNLESS SPECIFICALLY NOTED OTHERWISE ON DRAWINGS. <br />5. METER SOCKET AMPERAGEVOLTAGE, AND NUMBER OF PHASES SHALL RE AS NOTED ON THE <br />DRAWINGS. MANUFACTURED BY SQUARED COMPANY OR APPROVED EQUAL. IF HOST FACILITY <br />REQUIRES THE NEW SERVICE TO BE SUB -METERED FROM THE EXISTING SERVICE, SUB -METER SHALL <br />BE OF THE 10x OR 16x TYPE. <br />PATCH, REPAIR, AND PLANT ANY AREA THAT HAS BEEN DAMAGED IN THE COURSE OF THE <br />ELECTRICAL WORK <br />U. SERVICE CONDUITS SHALL BE GRAY SCH.40 PVC BURIED MIN. 36', EXCEPT THE SCR80 SHALL BE <br />USED UNDER ROADWAYS AND IN LOCATIONS SUBJECT TO CASUAL IMPACTS. BENDS SHALL BE MADE <br />USING'WIDE SWEEP" (12' MN. RADIUS) ELBOW FITTINGS. ANY CODE -REQUIRED RIGID STEEL <br />CONDUIT SHALL BE U.L LABEL GALVANIZED INSIDE AND OUTSIDE. CONDUIT SHALL EXTEND MN. 36' <br />BELOW GRADE WITH 'SWEEP ELBOWS (IT MIN. RADIUS) ENDING IN PVC TRANSITION FITTINGS. RIGID <br />CONDUIT IN CONTACT WITH EARTH SHALL BE 1/2 LAB -WRAPPED WITH HUNTS PROCESS NO. 3 <br />EXTENDING MIN. ABOVE GRADE. <br />V. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING HAVING U.L. LABEL FITTINGS SHALL BE <br />GLAND RING COMPRESSION TYPE <br />W, FLEXIBLE METALLIC CONDUIT SHALL HAVE U.L. LISTED LABEL AND MAY BE USED WHERE PERMITTED <br />BY CODE. FITTING SHALL BE 'JAKE' OR 'SQUEEZE' TYPE, SEAL TIGHT FLEXIBLE CONDUIT. NO SUCH <br />CONDUIT SHALL EXCEED SIX FEET IN LENGTH. <br />POLE AND ANTENNA INSTALLATION <br />A. IF REQUIRED, ERECT FURNISHED STRUCTURE. PRIOR TO ERECTION, CONTRACTOR MUST VERIFY <br />THAT CONCRETE HAS MET THE MINIMUM STRENGTH REQUIREMENTS AS WELL AS ANY OTHER <br />INSPECTION OR TESTING REQUIREMENTS. <br />B. INSTALL ANTENNAS AND UNES AS INDICATED ON THE DRAWINGS AND PER OWNER SPECIFICATION. <br />INSTALL ANTENNA AND CABLE MOUNTING HARDWARE AS INDICATED ON THE DRAWINGS OR <br />APPROVED BY THE CONSTRUCTION MANAGER ANTENNA INSTALLATION TO BE CONDUCTED BY FIELD <br />CREWS EXPERIENCED IN THE ASSEMBLE AND ERECTION OF ANTENNAS. TRANSMISSION LINES AND <br />SUPPORT STRUCTURE. <br />C. ASSIST OWNER TECHNICIANS IN PERFORMING SWEEP TEST OF INSTALLED COAX. <br />D. CONTRACTOR SHALL FOLLOW ALLAPPUCABLE STANDARDS INCLUDING, BUT NOT LIMITED TO: EIA 712 <br />(LATEST VERSION). FAA ADVISORY CIRCULAR AC70/7480-IA, FCC RULES 8 REGULATIONS <br />LANDSCAPING & SITE RESTORATION. <br />CONTRACTOR SHALL FURNISH. INSTALL, AND MAINTAIN LANDSCAPE WORK AS SHOWN ON THE <br />CONSTRUCTION DRAWINGS OR REQUIRED IN THE SPECIFICATIONS. <br />CONTRACTOR SHALL UTIUZE THE SERVICES OF ALANDSCAPE CONTRACTOR TO ENSURE THE <br />LANDSCAPING IS PROPERLY INSTALLED, WATERED. AND OTHERWISE MAINTAINED. CONTRACTOR <br />SHALL GUARANTEE LANDSCAPING FORA MINIMUM OF ONE (1) YEAR AND SHALL REPLACE ANY DEAD <br />OR VISIBLY DISTRESSED PLANTS WITHIN THIS PERIOD. <br />A. CONTRACTOR SHALL PROTECT SEEDED AREAS FROM EROSION THROUGH THE USE OF AN FRI SION <br />CONTROL MESH OR MULCH NET. <br />ALLTREES PLACED IN CONJUNCTION WITH A LANDSCAPE PLAN WILL BE WRAPPED. TIED WITH HOSE <br />PROTECTED WIRE, AND SECURE TO A STEEL ANGLE EXTENDING TWO FEET INTO THE GROUND ON <br />FOUR SIDES OF THE TREE. <br />C. ALLEXPOSED AREAS SHALL BE PROTECTED AGAINST WASHOUTS AND SOIL EROSION. <br />D. SEED AND FERTILIZER SHALL BE APPLIED TO SURFACE CONDITIONS TO ENCOURAGE ROOTING. RAKE <br />AREAS TO BE SEED TO EVEN THE SURFACE AND LOOSEN THE SOIL. SOW SEED IN TWO DIRECTIONS IN <br />TWICE THE QUANTITY RECOMMENDED BY THE SEED PRODUCER. <br />IT IS THE CONTRACTOR'S RESPONSIBILITY TO ENSURE GROWTH OF SEEDED AND LANDSCAPED <br />AREAS BY WATERING. CONTINUE TO REWORK BARE AREAS UNTIL COMPLETE COVERAGE IS <br />OBTAINED. <br />CONSULTANT <br />Edge <br />fie. IRA <br />6.64.1.9 VOICE <br />verizon <br />ENGINEER SEAL <br />I SEREST CERT, TEAT TINS PLAN <br />SET WAS PREPARED BY ME CR <br />NOTED IN THE SHEET POE% AND <br />FISOFESSIONA ENGINEER <br />UNDER THE LSWS CP ITN <br />STATE OF NEBRISEAL <br />EROJCO7 NO <br />ISAOSSES <br />LOCAL,. COOL <br />REDS DATE <br />OZONESIS <br />STRLICSURA ANALYSIS: <br />CATE <br />AVE 1325 <br />REPORT NO 913/.71 <br />DESCRIPTION: <br />05/22,6 <br />PER <br />S17106 <br />Eoo <br />42006 <br />SET <br />TYPE <br />FINAL <br />6 <br />SHEET <br />NUMBER <br />R-002 <br />EDGE CONSVITING ENGINEERS INC <br />