My WebLink
|
Help
|
About
|
Sign Out
Browse
202305977
LFImages
>
Deeds
>
Deeds By Year
>
2023
>
202305977
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2023 3:52:31 PM
Creation date
11/13/2023 3:50:37 PM
Metadata
Fields
Template:
DEEDS
Inst Number
202305977
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LS <br />c <br />re) <br />CN <br />0 <br />C�1 <br />6, <br />P <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FBER <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER, OVERLASH <br />MESSENGER CABLE <br />EXISTING CONDUIT <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLAC SPAN <br />NEW SUCK LOOP <br />EXISTING PUL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />EXISTING SLACK LOOP <br />EXISTING SPLICE CASE <br />DUSTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />ffl <br />co <br />0 <br />tig <br />0 <br />CO <br />C <br />0 <br />—0_ <br />0 <br />B B Goodin Bored (9..3' B) <br />C B conductor 9e.. 3/C) <br />CC 6 Coadel Cable <br />CCC B Camera Control Cade <br />CAC is Camera Detector Cede <br />CG ie CEO I Grand <br />CPC b Carrera Power Cede <br />DB B Direct Buried <br />DMSC B Dynamic Message Sign Cable <br />EDC Is Emergency Detector Cable <br />ETW B Electric Tracer Wire <br />BC a Existing <br />Fl B Fabric Interdud <br />RD is Fiber Locale Cable <br />FTW B Fber Tracer Wire <br />#15 is Instal <br />NT b trnaduct <br />LC M Lead -In Cade <br />M 4 Conduit Mounted (9 2' M) <br />MB Is Mein Une Conduit Group Bored (6)t 1/4' <br />MM Is Multi Mode Fber Cable <br />MT is Main Une ConduE Group Trenched MI 1/4' <br />NO N Number <br />p <br />OH Over Heed <br />PR 9 Pair d Communication (ie .6 PR) <br />REL B Relocate <br />REM Is Remove <br />RGS B Rigid Galvanized Steel <br />SC B Service Cable <br />SL Street Light <br />SM is Single Mode Fiber Cable <br />T B Conduit Trenched (9.3" T) <br />TW 9 Tracer Wire (black or green) <br />PCA243636-00006 <br />DOOMED C6.4CRETE ASSEMBLY <br />wow* 59 1 <br />n <br />AAA AAA., AA AAA <br />444rA.re 44.rs <br />leads Om4n.bn <br />UPN PULL BOX 24"X36%38' <br />AVOID WAX OP DANE <br />NOM <br />saw <br />Elel ea MI <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />J<FM <br />UNIT <br />QUANTITY <br />CONDUIT, 125' T <br />LF. <br />5 <br />CONDUIT, (2)1.25' B <br />LF. <br />1,794 <br />TRACER WIRE <br />T. <br />1,799 <br />UPN PULL BOX <br />EA <br />2 <br />UPN FLOWER POT <br />EA. <br />1 <br />RISER <br />EA. <br />1 <br />FIBER, 96 SM, OVERHEAD <br />T. <br />152 <br />FIBER, 96 SM, OVERHEAD SLACK STORAGE <br />LF. <br />100 <br />FIBER, 96 SM. UNDERGROUND <br />T. <br />1,798 <br />FIBER, 96 SM, UNDERGROUND SLACK STORAGE <br />LF. <br />170 <br />ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.' <br />FP PERSPECTIVE VIEWS <br />PROJECT NOTES <br />1. PARCEL DATA UTILITY INFORMATION, AND AERIAL IS APPROXIMATE AND SHOULD BE <br />TREATED AS SUCH. CONTRACTOR TO LOCATE AND INSTALL IN RIGHT-OF-WAY. <br />2. TIE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />URLRIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE ITTUTES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED N THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />3 UNLESS AGREED TO N WRITING N ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACILITES SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES N SOIL, <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM TIE FLOW UNE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION. <br />D. FORTY-EIGHT (481 INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LEE, AND <br />E. MANTNN A MINMUM OF 24' OF VERTICAL & HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />4. ALL POTHOLES N SIDEWALK PANELS WILL REOUIRE FULL PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />B. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />AERIAL FIBER INSTALLATION <br />1. INSTALL THE MESSENGER WITH CABLES TO SPECIFIED SAG AS SUBMITTED ON <br />COMM -SCOPE SAG DATA. <br />2 FIELD VERIFY ALL NEWLY INSTALLED CABLE/MESSENGER CLEARANCES ARE <br />CONSTRUCTED IN ACCORDANCE WITH THE NESC. <br />3. ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS AS STATED N THE CONTRACT. <br />4 GROUNDING TO BE INSTALLED AS STATED IN THE CONTRACT. <br />PRO.IECT ND. <br />017-0012 <br />SHEET NO <br />61 <br />Ten 11115,2018 <br />Oman: TAM <br />DeANE SB <br />A4prerad: DTs <br />r'RQIECT: 44348-V7W SC12 <br />olsson <br />vEIDDAKA'COIDIAGID Di AllIZITY9 IC. <br />Unite <br />mmn rr'DOW <br />d <br />PRIOR TO CONSTRUCTION: <br />CALL BIT FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTIUTES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVALABLE INFORMATION AND <br />THEREFORE, THEN LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBLITY OF THE <br />NDNDUAL CONTRACTORS TO <br />EXACTLY LOCATE ATO PROTECT <br />EACH 0/STING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.