PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY FACILITIES <br />MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND UTILITIES, <br />WHETHER SHOWN OR NOT. WILL BE LOCATED AND FLAGGED BY THE <br />UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO EXCAVATION <br />WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND UTILITIES <br />UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND IDENTIFIED TO <br />'THE SATISFACTION OF AU. PARTIES. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND AERIAL <br />UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS OTHERWISE AGREED TO IN WRITING IN ADVANCE OF THE <br />PROJECT CONSTRUCTION, THE DEPTH OF INSTALLED FACILITIES <br />SHALL BE, AT A MINIMUM. AS FOLLOWS: <br />A. FORTY-TWO (42) INCHES IN SOIL. <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE <br />FLOW UNE OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) <br />VERTICAL SLOPE. <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM <br />THE SURFACE OF SAID ROADWAY TO THE TOP OF THE <br />INSTALLATION. <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK <br />CHANNEL DESIGN FLOW LINE, AND <br />E. MAINTAIN A MINIMUM OF 24" OF VERTICAL 8 HORIZONTAL <br />SPACING FROM EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL <br />REPLACEMENT. <br />4 ANY CUT OR POTHOLE INA CONCRETE STREET PANEL WILL REQUIRE <br />FULL PANEL REPLACEMENT OR CORE REPLACEMENT WITH AN <br />APPROVED EPDXY. <br />5. ANY CUT OR POTHOLE IN AN ASPHALT STREET LANE WILL REQUIRE SEAM <br />TO SEAM ASPHALT MILLING AND REPLACEMENT. <br />6 ALL WORK ZONE TRAFFIC CONTROL, INCLUDING PEDESTRIAN CONTROL <br />MEASURES. SHALL BE IN COMPLIANCE WITH THE MUTCD, LATEST EDITION, <br />AND ADA. <br />7. PULL STRING SHALL BE INSTALLED IN EACH AND EVERY NEW CONDUIT. <br />AERIAL FIBER INSTALLATION <br />1. INSTALUADJUST MESSENGER CABLE AND FIBER PER NESC AND UTILITY <br />POLE OWNER REQUIREMENTS. <br />2. FIELD VERIFY ALL NEWLY INSTALLED MESSENGER CABLE AND FIBER <br />CLEARANCES ARE CONSTRUCTED IN ACCORDANCE WITH NESC AND UTILITY <br />POLE OWNER REQUIREMENTS. <br />3. ALL. ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS PER OWNER REQUIREMENTS. <br />4. GROUNDING TO BE INSTALLED PER NESC REQUIREMENTS. <br />CITY OF GRAND ISLAND NOTES <br />1 CONDUIT SHALL NOT BE PLACED BETWEEN THE CITY'S TRAFFIC SIGNAL <br />CABINET AND CONNECTING TRAFFIC SIGNAL CONDUIT/POLES. CONDUIT <br />MUST BE OFFSET A MINIMUM OF 5' FROM THE BASE OF ANY TRAFFIC SIGNAL <br />CABINET, TRAFFIC SIGNAL POLE, OR TRAFFIC SIGNAL PULL BOX. <br />2 CONTRACTOR WILL BE REQUIRED TO OBTAIN A PERMIT TO WORK IN THE ROW <br />(INCLUDING A TRAFFIC CONTROL PLAN) BEFORE ANY PHYSICAL WORK IS TO <br />TAKE PLACE. <br />3. LOCATE FLAGS SHALL BE REMOVED AFTER THE "EXCAVATOR" HAS <br />DETERMINED THE WORK IS COMPLETE. <br />4 IF SIGNAL CONDUIT/WIRE HAS TO BE CROSSED THE NEW LINE SHALL BE A <br />MINIMUM OF 6' DEEP WHERE CROSSING AND THE EXISTING SIGNAL CONDUIT <br />SHALL BE POTHOLED AND VERIFIED ON-SITE PRIOR TO BORING. <br />5. STREETS DIVISION SHALL BE CONTACTED PRIOR TO WORK BEGINNING AT <br />308-385-5322. ANY KEYHOLE POTHOUNG LOCATIONS IN THE ROADWAY <br />SHALL BE APPROVED BY THE STREETS DIVISION AND SHALL BE FILLED <br />WITHIN FIVE DAYS OF POTHOLING. <br />PROJECT NO. <br />SHEET NO. <br />UPN: P0-40182 <br />2 <br />JEO: 230288.08 <br />DMA 23A44Y-2023 <br />Drawn: <br />Checked: <br />Appro.,' <br />BRB <br />MAF <br />MAF <br />Unite <br />MASERGY <br />205 E ROBERTS ST <br />GRAND ISLAND, NE <br />Know what s below. <br />Call before you dig. <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAWS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND DRAINAGE <br />STRUCTURES HAVE BEEN PLOTTED <br />FROM AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS MUST <br />BE CONSIDERED APPROXIMATE ONLY. <br />IT IS THE RESPONSIBILITY OF THE <br />INDMDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXI51150 UTILITY BEFORE AND <br />DURING ACTUAL CONSTRUCTION. <br />JEO CONSULTING GROUP INC <br />GENERAL NOTES N. <br />NI <br />cD <br />