202300863 <br />00 <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />BORED CONDUIT <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER, OVERLASH <br />MESSENGER CABLE <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />EXISTING SLACK LOOP <br />EXISTING SPUCE CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />1 <br />co <br />0 <br />co <br />0 <br />CABLE AND CONDUIT DESIGNATIONS <br />• <br />Bis Conduit Bored (i.e. 3" B) <br />C is Conductor (i.e. 3/C) <br />CC is Coaxial Cable <br />CCC is Camera Control Cable <br />CDC is Camera Detector Cable <br />CG 4 Circuit Ground <br />CPC is Camera Power Cable <br />DB R Direct Buried <br />DMSC 4 Dynamic Message Sign Cable <br />EDC is Emergency Detector Cable <br />ETW is Electric Tracer Wire <br />EX is Existing <br />Fl is Fabric Interduct <br />FLC is Fiber Locate Cable <br />FTW i5 Fiber Tracer Wire <br />INS is Install <br />INT is Intraduct <br />LC is Lead -In Cable <br />M is Conduit Mounted (i.e. 2" M) <br />MB is Main Une Conduit Group Bored (6) 1 1/4" <br />MM 4 Multi Mode Fiber Cable <br />MT 4 Main Line Conduit Group Trenched (6) 1 1/4" <br />NO is Number <br />OH is Over Head <br />PR 'a Pair of Communication (i.e. 6 PRI <br />REL is Relocate <br />REM is Remove <br />RGS is Rigid Galvanized Steel <br />SC is Service Cable <br />SL is Street light <br />SM is Single Mode Fiber Cable <br />T Is Conduit Trenched (I.e. 3'1) <br />TW is Tracer Wire (black or green) <br />BOC is Back Of Curb <br />EOP is Edge Of Pavement <br />PCA243636-00006 <br />PCT PDLWER CO CRETE. .NLr <br />PC <br />• o pHtt aan•How <br />SN".se,.na.a <br />• <br />"„Nwew <br />newbasts <br />CanpoM>4 for 1nes6ecwr" <br />M! MMIUM <br />UPN PULL BOX, 24"X36"X36" <br />36" <br />AvgO WALLA OR DRIVE <br />12" <br />UPN PULL BOX INSTALLATION <br />\ 6" <br />SUMMARY OF QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 1.25" 8 <br />LF. <br />370 <br />TRACER WIRE <br />LF. <br />185 <br />SPLICE ENCLOSURE <br />EA. <br />1 <br />TEMPORARY TRAFFIC CONTROL FOR CONSTRUCTION <br />LS. <br />1 <br />FIBER, 24 SM, UNDERGROUND <br />LF. <br />185 <br />FIBER, 24 5M, UNDERGROUND SLACK STORAGE <br />LF. <br />180 <br />"ALL FI800 (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS AND POLES. QUANTITIES DO <br />NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK." <br />PROJECT N0. <br />SHEET N0. <br />UPN: 00-37704 <br />JEO: 00438 97 <br />Dale. O1-FEB-Z0ZJ <br />Drawn: MAF <br />Iter. JOH <br />AOprOred: MAF <br />Unite <br />2032 BRENTWOOD BLVD <br />5 POINTS - PS 2 OF 2 <br />GRAND ISLAND, NE <br />Know what's below. <br />Call below youdly. <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE. <br />ELECTRIC. GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND DRAINAGE <br />STRUCTURES HAVE BEEN PLOTTED <br />FROM AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS MUST <br />BE CONSIDERED APPROXIMATE ONLY. <br />ITIS THE RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXISTING UTILITY BEFORE AND <br />DURING ACTUAL CONSTRUCTION. <br />LEO CONSULTING GROUP INC <br />DETAILS <br />