PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY FACILITIES <br />MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND UTIUTIES, <br />WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED BY THE <br />UTIUTIES UPON THE REQUEST OF THE CONTRACTOR. NO EXCAVATION <br />WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND UTILITIES <br />UNTIL ALL SUCH FACIUTIES HAVE BEEN LOCATED AND IDENTIFIED TO <br />THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND AERIAL <br />UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS OTHERWISE AGREED TO IN WRITING IN ADVANCE OF THE <br />PROJECT CONSTRUCTION, THE DEPTH OF INSTALLED FACILITIES <br />SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A. FORTY-TWO (42) INCHES IN SOIL <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE <br />FLOW LINE OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) <br />VERTICAL SLOPE. <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM <br />THE SURFACE OF SAID ROADWAY TO THE TOP OF THE <br />INSTALLATION. <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK <br />CHANNEL DESIGN FLOW LINE, AND <br />E. MAINTAIN A MINIMUM OF 24' OF VERTICAL 8 HORIZONTAL <br />SPACING FROM EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL <br />REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREET PANEL WILL REQUIRE <br />FULL PANEL REPLACEMENT OR CORE REPLACEMENT WITH AN <br />APPROVED EPDXY. <br />5. ANY CUT OR POTHOLE IN AN ASPHALT STREET LANE WILL REQUIRE SEAM <br />TO SEAM ASPHALT MILLING AND REPLACEMENT. <br />6. ALL WORK ZONE TRAFFIC CONTROL. INCLUDING PEDESTRIAN CONTROL <br />MEASURES. SHALL BE IN COMPLIANCE WITH THE MUTCD, LATEST EDITION, <br />AND ADA. <br />7. PULL STRING SHALL BE INSTALLED IN EACH AND EVERY NEW CONDUIT. <br />AERIAL FIBER INSTALLATION CITY OF GRAND ISLAND NOTES <br />1. INSTALUADJUST MESSENGER CABLE AND FIBER PER NESC AND UTIUTY <br />POLE OWNER REQUIREMENTS. <br />2. FIELD VERIFY ALL NEWLY INSTALLED MESSENGER CABLE AND FIBER <br />CLEARANCES ARE CONSTRUCTED IN ACCORDANCE WITH NESC AND UTILITY <br />POLE OWNER REQUIREMENTS. <br />3. ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS PER OWNER REQUIREMENTS. <br />4. GROUNDING TO BE INSTALLED PER NESC REQUIREMENTS. <br />1 CONDUIT SHALL NOT BE PLACED BETWEEN THE CITY'S TRAFFIC SIGNAL <br />CABINET AND CONNECTING TRAFFIC SIGNAL CONDUIT/POLES. CONDUIT <br />MUST BE OFFSET A MINIMUM OF 5' FROM THE BASE OF ANY TRAFFIC SIGNAL <br />CABINET. TRAFFIC SIGNAL POLE, OR TRAFFIC SIGNAL PULL BOX. <br />2. CONTRACTOR WILL BE REQUIRED TO OBTAIN A PERMIT TO WORK IN THE ROW <br />(INCLUDING A TRAFFIC CONTROL PLAN) BEFORE ANY PHYSICAL WORK IS TO <br />TAKE PLACE. <br />3. LOCATE FLAGS SHALL BE REMOVED AFTER THE 'EXCAVATOR' HAS <br />DETERMINED THE WORK IS COMPLETE. <br />4. IF SIGNAL CONDUIT/WIRE HAS TO BE CROSSED THE NEW LINE SHALL BE A <br />MINIMUM OF 6' DEEP WHERE CROSSING AND THE EXISTING SIGNAL CONDUIT <br />SHALL BE POTHOLED AND VERIFIED ON-SITE PRIOR TO BORING. <br />PROJECT NO. <br />SHEET NO <br />UPN: P0-39224 <br />LEO: 200439.88 <br />Date: 1&N0V-2022 <br />Drawn BRB <br />Check., MAB <br />Amapa.- LIB <br />Unite <br />AT&T IRS <br />GRAND ISLAND. NE <br />Know what's below. <br />Call before you dig. <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE. <br />ELECTRIC. GAS HAAMHS. CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTIUTIES AND DRAINAGE <br />STRUCTURES HAVE BEEN PLOTTED <br />FROM AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS MUST <br />BE CONSIDERED APPROXIMATE ONLY. <br />ITIS THE RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXISTING UTILITY BEFORE AND <br />DURING ACTUAL CONSTRUCTION. <br />3 LEO CONSULTING GROUP INC <br />GENERAL NOTES <br />