STAKING SHEET - UNDERGROUND <br />Company: OPTK Networks Exchange:Grand Island <br />CONSTRUCTION PROJECT NOTES <br />1. The State, County. City personnel shall be notifiea 3 minimum of forty eight (48) hours in advance of Initial project <br />construction <br />2 The utility company and the contactor(s) are responsible to have at least one person on the job at all times, that 5 <br />'see supervisor' certfied. <br />3. The contractor shall adhere to the current permit aha contract specifications <br />4. The locations of al i aenat arca underground utility facilities may not be Indicated on the proem plans. The contractor <br />is required to contact the Nebraska and Colorado 811 one call notification censer (dial 8t 1) forty-eight (48( hours <br />poor to working in the city right array. No excavation will be pemuUed in the area of the underground utilities until <br />ali facilites have been located and identified to the satisfaction of all parties. The aantractor shall be responsible for <br />protection of all underground and aerial utilities and nfrastructure. <br />Whenever underground faolties are on close proximity to the proposed pathway location or whenever the vertical <br />iocabon of the underground facility Is unknown, the contractor snail use special measures to determine the locations <br />of such underground facilites. <br />a the contractor is conductng the excavation by dogging from the surface wren in a close proximity to :he <br />underground fac4rtes the contractor snail use nand digging. hydro excavating. or ear excavating to locate such <br />facility. <br />b. t <br />the contractor is Cpn0udting the excavation by tunneling or boring. the contractor shall deterrnne the vertical <br />location of the underground faokty by pothokng or any other method approved by the director of public works and <br />utilrbes <br />t. Project plans shat: dimension new facilites being nstalleo <br />7 sinless agreed to in venting n advance the depth of instated facilites n Crty and county row snail be ata minimum <br />as follows. <br />a Forty-eight (48} inches in soil <br />b. Forty-eight (484 inches below a projecle0 slope from the flow lire of a ditch ata three (3 ) horizontal and one 111 <br />vertical slope_ <br />c Forty-eight (48) inches unser a roadway measured from the surface of said roadway to the top of the nst341ateon <br />d Sixty (801 inches under a storm water or creek channel design bottom or pipe. and <br />e. Maintain a minimum of twenty-four 1241 ernes of vertical and horaontai spacing from existing sautes <br />f Be located as far from the existing or proposed curb line as possible to avoid potential future conflicts <br />8. AN non -street surface materials that are disturbed by excavation and bacltf4kng operations shall be replaced ana <br />restored <br />6. City are county street surface materials disturbed shay be backfilled. tempest and repaved by city or county forces <br />or approved paving oontractor <br />If sidewalk, wheel chair rarnps or any portion of the pedestnan facilities are removed or dosed, a pedestnan detour <br />shalt be established and maintained during the time of the closure and the entire peoestnan faality shall be restored <br />enthin seventy-two l72) hours. unless the contractor provioes a hard surface alternate route approved by the city or <br />county <br />1. All pedestrian detours and any reconstruction of pedestrian facilites snarl nee: current Amencans win Disablkty <br />Act (ADA) standards and specifications. <br />2. Al pedestrian detours shall be part of an approved Traffic Control Plan (TCP i. <br />'3 AN holes made in the streets for the purpose of performing vacuum eacavabons to locate underground utilities shall <br />oe res:ored to their original condition wrtr the reinstated core flush with and in the onginal orientation as the existing <br />surface matcning existing pavement surface appearance. <br />4 When the contractor Is riot actively working, all equipnenht, fencing, debn5, etc. Shall not be placed within the <br />nangular area required for sight orstarece of vehicles exiting or entenng an adjacent property or lntersecvon. <br />41 excavations shat' be adequately fenced and covered when contractor is not present or project site left <br />unattended. <br />16. No lane closures allowea on artenai streets during AM and PM peak hours <br />17. Alt work zone traffic Wntrol. Including pedestrian control measures, shall be in compliance with the MUTCD and <br />ADA <br />18 The contractor shall maintain a set of "as built" pans on site with dimensioning These plans snail be presented <br />upon request <br />19 Final "as -built" pans sial be filed with city anthor county withn 30 clays of the completion of the project. <br />20 The oontracmr shall follow construction standards pertaining to the lateral corndor facility placement and minimum <br />depth requirements and clearance requirements of other facilities. <br />21 A current State. County, or Crty permit snail be mairltained on each wort site by the contractor. Tne contractor <br />shat present such permit upon request. <br />22. Any field adjustments to Installation of faal14es, which vary from the plans that nave been submitted and approved <br />during the permit application process, 5/134 comply with the following. <br />a The contractor must stop wort immediately aha cornea the facility owner of the proposed changes <br />b. The facility owner's representatve shall contact the city. county or state night -o( -way construction inspector and <br />',royale them cath the detaiis <br />c. The ROW inspector will make a detenninabon on how to proceed. This oetemunatnn may range from approval <br />over the phone or via erne/ to delaying the project until plans can be updated and appropriate review can be <br />cOrxfutted. <br />23. Stake mounted warning signs ana marker posts (BM531 to to placed where appropriate <br />24. As conduit arca fiber is to be instaneo a: the back of the roadway ROW unless otherwise notes. <br />25. Leave 120' loops 80'talls at spkoe points) for rraahnne fiber n vaults <br />Conduit shall not be placed between the Cay s traffic signal cabinet and connectng traffic signal <br />conduit/poles <br />Conduit ,mast be offset a nvnmum of 5 from the base of any traffic signal cabinet, traffic signal <br />pole. or traffic signal pull lox <br />Contractor will be required to obtain a permit 10 work in the ROW (including a traffic control plan) <br />be/We any physical work Is to take place. <br />Locate flags shag be removed after the -excavator' has determined the work is complete <br />IF SIGNAL CONOUITANIRE HAS TO BE CROSSED THE NEW LINE SMALL BE A MINIMUM <br />OF 6' DEEP WHERE CROSSING AND THE EXSTING SIGNAL CONDUIT SHALL BE <br />POTHOLED AND VERIFIED ON-SITE PRIOR TO BORING. <br />
The URL can be used to link to this page
Your browser does not support the video tag.