STAKING SHEET - UNDERGROUND <br />Company: OPTK Networks Exchange: Grand Island <br />CONSTRUCTION PROJECT NOTES <br />The State. County. City personnel shall be notified a minimum of forty eight (481 hours In advance of Initial project <br />oonstrudtlon. <br />2. The utility company and the contractorls) are responsible to have at least one person on the job at at times. that is <br />'5ne supervisor' certified. <br />3. The contractor shall adhere to the current permit and contract specifications <br />4 The locatons of all aerial and underground utility facilities may not be indicated on the project puns The contractor <br />is required to contact the Nebraska and Colorado 811 one call notification center tdial 8111 forty-eight (48 hours <br />pnor to working in re city nght of way. No excavaton wit be pemutted in the area of the underground utilities until <br />all facilites have been located and Identified to the satisfaction of all parties. The oonbactor shall be responsible for <br />protection of at underground and aenal utilities and infrastructure. <br />0. Whenever underground facilities are In dose proximity to the proposed pathway location or whenever the vertical <br />location of the underground facility is unknown, the contractor shall use special measures to determine the iodations <br />of such underground faolithes. <br />a If the contractor Is conducting the excavation by digging from the surface. when in a dose proximity to the <br />underground facilitesthe contractor shall use nand digging. hydro excavating. or air excavating to locate such <br />facility. <br />b. If the contractor is conducting the excavauon by art -meting a boring. the contractor shall determine the vertical <br />location of the underground facility by potholing or any other method approved by the director of public works and <br />J111ite5 <br />6. Project plans shat, dimension new facilities being installed <br />7. Unless agreed to in wntng in advance the depth of mstalIeo facdrtes In city and county row shall be ata minimum <br />as follows <br />a. Forty-eight (481 inches In soil <br />G. Forty-eight 081 inches below a projected sope from the Row line of a ditch at a three (31 horizontal and one 111 <br />vertical slope. <br />c Forty-eight (48, inches under a roadway measured from the surface of said roadway to the top of the installation. <br />d. Soty (001 inches under a storm water or creek channel design bottom or pipe, and <br />e. Maintain a minimum of twenty-four 124) Inches of vertical and horttontal spacing from existing utilities <br />f Be Iodated as 'ar from the existing or proposed curb line as possible to avoid potentia) future conflicts <br />8. Al non -street surface materials that are disturbed by excavation and backflling operations 5rhali be replaced ane <br />restored <br />0. City and county street surface materials disturbed shall be backfilledt tamped and repaved by oty or d0Unty forces <br />or approved paving contractor <br />if sidewalkwheel chair ramps or any porton of the pedestnan facilites are removed or dosed, a pedestnan detour <br />snap be established and maintained dung the time of the closure and the entire pedestrian facility snail be restored <br />within seventy-two ,721 hours. unless the contractor provides a nam surface alternate route approved by the city or <br />county <br />'1 All pedestnan detours and any reoonstruction of pedestnan fadlrties shall meet current Amencans with Disability <br />Ad (ADA) standards and specifications. <br />2. All pedestrian detours shat toe pan of an approved Traffic Control Plan (TCP) <br />13. All holes made in the streets for the purpose of performing vacuum excavations to locate underground utilities shall <br />be restored to their onginal condrbwl oath the reinstated core Rush with and in the onginal onentation as the existing <br />surface matching existing pavement surface appearance <br />14. When the contractor I5 not actively workingall equipment, fencing, debns, etc. Shall not be placed within the <br />triangular area required for sight distance of vehicles exiling or entenng an adjacent property or intersection. <br />15 All excavations shall be adequately fenced and covered when contractor is not present or project site left <br />unanerded. <br />16 No lane closures allowed on arterial streets dung AM and PM peak hours. <br />17 All work zone traffic contra, inducing pedestrian control measures. shall be in compliance with the MUTCD and <br />ADA <br />18 The contractor shall maintain a set of "a5 built" plans on site with dimensioning These plans shall be presented <br />upon request. <br />10 Final "as -built'' pans shall be filed with dry andlor county within 30 days of the completion of the project. <br />20. The contractor shall follow construction standards pertaining to the lateral candor facility placement and minimum <br />depth requirements and clearance requirements of other faoiliues <br />21. A current State. County or City permit shall be maintained on each work site by the contractor The contractor <br />5h311 present such permit upon request. <br />22. Any field adjustments to installation 0113014s. which vary from the puns that have been submmeo and approved <br />during the permit application process, shat+ comply won the folnwing <br />a The centractor must stop work immediately and contact the facility owner of the proposed changes <br />b The facility owners representative shall contact the oty, wunty or state right-of-way construction inspector and <br />provide them with the details. <br />c. The ROW inspector will make a determination on tow to proceed. This determination may range from approval <br />over the phone or via email to delaying the project until puns can toe updated and appropriate review can be <br />conducted. <br />23. Stake mounted teaming signs aro marker posts (134.453) to be placed Where appropriate. <br />24. All conduit and fiber is to be Instated at the back of the roadway ROW unless otherwise noted. <br />25. Leave 120' bops (60' tails at splice points) for mainline fiber in vaults <br />