Laserfiche WebLink
PROJECT NOTES AERIAL FIBER INSTALLATION <br />1 THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTIUTY FACILITIES <br />MAY NOT BE INDICATED ON THESE PLANS UNDERGROUND UTILITIES. <br />WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED BY THE <br />UTILITIES UPON THE REOUEST OF 780 CONTRACTOR NO EXCAVATION <br />WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND UTILITIES <br />UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND IDENTIFIED TO <br />THE SATISFACTION OF ALL PARTIES THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND AERIAL <br />UTILITIES AND CONSTRUCTIONS <br />2 UNLESS OTHERWISE AGREED TO IN WRITING IN ADVANCE OF THE <br />PROJECT CONSTRUCTION. THE DEPTH OF INSTALLED FACILITIES <br />SHALL BE. AT A MINIMUM. A5 FOLLOWS'. <br />A FORTY-TWO (42) INCHES IN SOIL <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE <br />FLOW UNE OFA DITCH ATA THREE (3) HORIZONTAL AND ONE (1) <br />VERTICAL SLOPE <br />C FORTY-EIGHT (461) INCHES UNDER A ROADWAY MEASURED FROM <br />THE SURFACE OF SAID ROADWAY TO THE TOP OF THE <br />INSTALLATION <br />D FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK <br />CHANNEL DESIGN FLOW LINE. AND <br />E MAINTAIN A MINIMUM OF 24.0F VERTICAL 8 HORIZONTAL <br />SPACING FROM EXISTING UTIUTIES. <br />3 ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL <br />REPLACEMENT <br />4 ANY CUT OR POTHOLE IN A CONCRETE STREET PANEL WILL REQUIRE <br />FULL PANEL REPLACEMENT OR CORE REPLACEMENT WITH AN <br />APPROVED EPDXY. <br />5 ANY CUT OR POTHOLE IN AN ASPHALT STREET LANE WILL REOUIRE SEAM <br />TO SEAM ASPHALT MILLING AND REPLACEMENT <br />6 ALL WORK ZONE TRAFFIC CONTROL. INCLUDING PEDESTRIAN CONTROL <br />MEASURES. SHALL BE IN COMPLIANCE WITH THE MUTCD. LATEST EDITION. <br />AND ADA <br />T INSTALL THE MESSENGER WITH CABLES TO SPECIFIEO SAG AS SUBMITTED <br />ON COMM -SCOPE SAG DATA <br />2. FIELD VERIFY ALL NEWLY INSTALLED CABLE/MESSENGER CLEARANCES ARE <br />CONSTRUCTED IN ACCORDANCE WITH THE NE5C. <br />3 ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH W000 PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS AS STATED IN THE CONTRACT <br />4 GROUNDING TO BE INSTALLED AS STATED IN THE CONTRACT <br />IIR➢.0C1 W <br />84E6 NO <br />VPII PO4 MEI <br />.EO: 200136.26 <br />0.a. 264241.7022 <br />Dlw..• 1017 <br />MRF <br />Mitp <br />DIAMOND PLASTICS <br />1212 JOHNSTOWN RD <br />GRAND ISLAND NE <br />Kno. WI14Ol below. <br />Cali before you dig <br />CALL Eft FOR LOCATION 01 <br />UNDERGROUND TELEPHONE <br />ELECTRIC W MANS. WILE <br />TELEVISION AND OTHER UEIOTIES <br />EX66TNG UNOERGROLIND 060 <br />OVERHEAD UTILITIES AND ORABMGE <br />STRUCTURES HAVE BEEN P.OTEO <br />FROM PARABLE INFORMATION AND <br />THEREFORE. TFEF LOCATORS MUST <br />BE CONSIDERED APPROSIMATE ONI Y <br />.1 TIE AETH'ONv4ANY OF HA <br />WWI DJA1 CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT EACH <br />EXISTING UTILITY BEFORE ANO <br />DURING ACTUAL CONSTRUCTION <br />L0 CONSULTING GROUP INC <br />GENERA( NOTES <br />