Laserfiche WebLink
m� <br />of <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT--------------------������������������ <br />EXISTING AERIAL FIBER <br />BORED CONDUIT .....-.-.-----.-.-.-.-...-...-.-.....-.-.-.-----.-.-.-.-----.-----... <br />TRENCHED CONDUIT................................................................... <br />QUANTITY <br />NEW AERIAL FIBER <br />LF. <br />NEW AERIAL FIBER, OVERLASH <br />TRACER WIRE <br />LF. <br />MESSENGER CABLE <br />UPN PULL BOX <br />EA. <br />NO CITY RECIPIENT FIBER........................................................... <br />EXISTING CONDUIT ------------------------------------- <br />EXISTING SIGNAL CONDUIT ------ww--w---------------------- <br />ROW <br />FIBER, 96 SM UNDERGROUND SLACK STORAGE <br />NEW PULL BOX <br />j] <br />NEW PEDESTAL <br />Z <br />NEW POLE <br />OO <br />NEW DOWN GUY <br />—� <br />NEW RISER <br />NEW SLACK SPAN <br />EA <br />NEW SLACK LOOP <br />00 <br />EXISTING PULL BOX <br />Q <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />OO <br />EXISTING SLACK LOOP <br />CID <br />EXISTING SPLICE CASE <br />rp <br />EXISTING MANHOLE <br />O <br />SIGN <br />__9L_ <br />BARRICADE <br />A -1106--a <br />DRUM <br />0 <br />BORE PIT <br />❑ <br />ARROW PANEL <br />FT 71 <br />CABLE AND CONDUIT DESIGNATIONS <br />B is Conduit Bored (ie..3" B) <br />C is conductor (ie.. 3/C) <br />CC is Coaxial Cable <br />CCC is Camera Control Cable <br />CDC is Camera Detector Cable <br />CG is Circuit Ground <br />CPC is Camera Power Cable <br />DB is Direct Buried <br />DMSC is Dynamic Message Sign Cable <br />EDC is Emergency Detector Cable <br />ETW is Electric Tracer Wire <br />EX is Existing <br />FI is Fabric Interduct <br />FLC is Fiber Locate Cable <br />FTW is Fiber Tracer Wire <br />INS is Install <br />INT is Intraduct <br />LC is Lead -In Cable <br />M is Conduit Mounted (ie..2" M) <br />MB is Main Line Conduit Group Bored (6) 1 1/4" <br />MM is Mufti Mode Fiber Cable <br />MT is Main Line Conduit Group Trenched (6) 1 1/4" <br />NO is Number <br />OH is Over Head <br />PR is Pair of Communication (ie..6 PR) <br />REL is Relocate <br />REM is Remove <br />FIGS is Rigid Galvanized Steel <br />SC is Service Cable <br />SL is Street Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched (ie..3" T) <br />TW is Tracer Wire (black or green) <br />KiA2g-MON <br />2r -3 -aa <br />:=C;=* <br />=C; WA -141 S <br />Rw ea.. sonata nrweree (Sade <br />r wrd curl OnrewA <br />LOAD 111101111111111111 <br />WWW" Tft - Prbq La. 9f00wR <br />cvdo w <br />•WUC3b <br />•ASTM C 957 <br />• ANSUSCTE n <br />RATIII1111L• <br />• skid rotor. aw <br />arliww 1601now <br />• rr.+n �O na eo- <br />- e+evr awe naw <br />AMreAel MMW Mew <br />weAYwd w M www <br />CompoOA "for IMrenOnecWr� <br />3ae....e Av.r <br />eu..r..cre.r OWN/ <br />wi.rarm <br />w1.1Aw3Q 11x1 <br />Insrda DWwwaions <br />I_41h WWIn O <br />33W7- 271St-_____ _ 3T <br />UPN PULL BOX, 24"X36"X36" <br />AVOID WALK OR DRIVE <br />\//ice \•�lj���//i�j <br />.L y68y •y�p8 CUT PARALLEL 'yg°e8•a •�o <br />TO LID •-. •$U. ROCK <br />ROCK <br />FABRIC / eab f. ��.•°•O ,HgO�SE CLAMPS VI..°�.4j"�b°�^°.'• \ FABRIC <br />x.48a°8 e: g .a'e�; <br />Fez <br />• 3• .r".°o: °p sod?o$°°'�o' `irel <br />UPN PULL BOX INSTALLATION <br />REV: A.1 <br />SUMMARY OF QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 2" B <br />LF. <br />2,850 <br />TRACER WIRE <br />LF. <br />2,850 <br />UPN PULL BOX <br />EA. <br />1 <br />FIBER, 96 SM, UNDERGROUND <br />LF. <br />2,850 <br />FIBER, 96 SM UNDERGROUND SLACK STORAGE <br />LF. <br />240 <br />*ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.` <br />PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILITIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. TO AVOID CONFLICTS WITH NEW ROAD CONSTRUCTION AND RELOCATION <br />OF OTHER UTILITIES, THE DEPTH OF FACILITIES SHALL BE AT A MINIMUM <br />OF TEN -FEET (10') BELOW EXISTING GRADE. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />017-0078 1 G.1 <br />Date: 02\12\2021 Drawn: IMH <br />Checked: STS <br />Aooraved: GTS <br />PROJECT: 29073 -ROAD MOVE <br />CAPITAL & "N" <br />olsson� <br />nwalw 1 <br />NoMw oftOOAR� <br />PRIOR TO CONSTRUCTION <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE, THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />y\ONpL }CI V14 F <br />O � <br />a GRE ORY T. A <br />SEIB <br />E-15150 <br />a-la*coal <br />ATF OF NE8PP5 <br />GENERAL NOTES <br />