Laserfiche WebLink
LEGEND OF SYMBOLS <br />QUANTITIES <br />EXISTING CONDUIT--------r.---a.------- <br />MA243636-OOM <br />EXISTING CONDUIT ------------------------------------- <br />POLYMER CONCRETE ASSEMBt <br />EXISTING AERIAL FIBER <br />LF. <br />ROW <br />2r a 3T.3T <br />BORED CONDUIT.-.-.-.—.-.-.-.-.—.-.-.-.-.-.-.-.-.-.-.-.-.—.-.-.-.-.w.—.-.-.-.-.-., <br />EawFwuc�in'ac" <br />TRACER WIRE <br />F� BOOL aaaY.IsOadr <br />TRENCHED CONDUIT................................................................... <br />at &- da lorar�YWNft <br />NEW AERIAL FIBER <br />LOAD RAIRM <br />UPN PULL BOX <br />ftWW al Traec. PMue Lot. S4WAR <br />NEW AERIAL FIBER, OVERLASH <br />cmilmm ID <br />tic EE2 <br />ArlsyscrE n <br />MESSENGER CABLE <br />QUANTITIES <br />NO CITY RECIPIENT FIBER.•.......•.........•.............•.•.•...•...•...•.•...•.•. <br />EXISTING CONDUIT ------------------------------------- <br />QUANTITY <br />EXISTING SIGNAL CONDUIT --------------------------------- <br />LF. <br />ROW <br />CONDUIT, 2" T <br />LF. <br />NEW PULL BOX <br />TRACER WIRE <br />El <br />NEW PEDESTAL <br />RISER <br />EA. <br />NEW POLE <br />UPN PULL BOX <br />OO <br />NEW DOWN GUY <br />FIBER, 96 SM, UNDERGROUND <br />—� <br />NEW RISER <br />FIBER, 96 SM, UNDERGROUND SLACK STORAGE <br />LF. <br />NEW SLACK SPAN <br />FIBER, 24 SM, UNDERGROUND <br />{f� <br />NEW SLACK LOOP <br />FIBER, 24 SM, UNDERGROUND SLACK STORAGE <br />CO <br />EXISTING PULL BOX <br />0 <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />OO <br />EXISTING SLACK LOOP <br />00 <br />EXISTING SPLICE CASE <br />W) <br />EXISTING MANHOLE <br />O <br />SIGN <br />BARRICADE <br />s w w <br />DRUM <br />0 <br />BORE PIT <br />ARROW PANEL <br />RT C <br />CABLE AND <br />CONDUIT DESIGNATIONS <br />B is Conduit Bored (ie..3" B) <br />LC is Lead -In Cable <br />C is conductor (ie.. 3/C) <br />M is Conduit Mounted (ie..2" M) <br />CC is Coaxial Cable <br />MB is Main Line Conduit Group Bored (6) <br />CCC is Camera Control Cable <br />MM is Multi Mode Fiber Cable <br />CDC is Camera Detector Cable <br />MT is Main Line Conduit Group Trenched <br />(6) 1 1/4" <br />CG is Circuit Ground <br />NO is Number <br />CPC is Camera Power Cable <br />OH is Over Head <br />DB is Direct Buried <br />PR is Pair of Communication (ie..6 PR) <br />DMSC is Dynamic Message Sign Cable <br />REL is Relocate <br />EDC is Emergency Detector Cable <br />REM is Remove <br />ETW is Electric Tracer Wire <br />FIGS is Rigid Galvanized Steel <br />EX is Existing <br />SC is Service Cable <br />A is Fabric Interduct <br />SL is Street Light <br />FLC is Fiber Locate Cable <br />SM is Single Mode Fiber Cable <br />FTW is Fiber Tracer Wire <br />T is Conduit Trenched (e..3" T) <br />INS is Install <br />TW is Tracer Wire (black or green) <br />INT is Intraduct <br />FEATURM' <br />usoAiaus AFna.a <br />:sa�.+.n�ewr�a <br />• sua..wn ao.w <br />• eow+w a..t aaa. <br />• coon aaaRaq �.a ea. <br />• aaspr a.n r.w <br />AM EMN poftd MMM <br />..0—d a. E.laa.aa <br />e <br />oal6aa for <br />c.rk.,�eaor <br />.i mAa. <br />aa. m oa3x (rn <br />Inside DEnensiora <br />�.npn -wan o.on - <br />--- --- — --- <br />1TWIT - 21 15117 - 33' <br />UPN PULL BOX, 24"X36"X36" <br />EEv: Al <br />SUMMARY OF <br />QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 2" B <br />LF. <br />1,754 <br />CONDUIT, 2" T <br />LF. <br />12 <br />TRACER WIRE <br />LF. <br />1,766 <br />RISER <br />EA. <br />2 <br />UPN PULL BOX <br />EA. <br />4 <br />FIBER, 96 SM, UNDERGROUND <br />LF, <br />1,232 <br />FIBER, 96 SM, UNDERGROUND SLACK STORAGE <br />LF. <br />240 <br />FIBER, 24 SM, UNDERGROUND <br />LF. <br />528 <br />FIBER, 24 SM, UNDERGROUND SLACK STORAGE <br />LF. <br />160 <br />`ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.* <br />PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILITIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A. FORTY-TWO (42) INCHES IN SOIL, <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW LINE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LINE, AND <br />E. MAINTAIN A MINIMUM OF 24" OF VERTICAL & HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />AERIAL FIBER INSTALLATION <br />1. INSTALL THE MESSENGER WITH CABLES TO SPECIFIED SAG AS SUBMITTED ON <br />COMM—SCOPE SAG DATA. <br />2. FIELD VERIFY ALL NEWLY INSTALLED CABLE/MESSENGER CLEARANCES ARE <br />CONSTRUCTED IN ACCORDANCE WITH THE NESC. <br />3. ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS AS STATED IN THE CONTRACT. <br />4. GROUNDING TO BE INSTALLED AS STATED IN THE CONTRACT <br />Date: 02\16\2021 Checked: STS <br />Ap roved: GTS <br />PROJECT: 28684—ROAD MOVE <br />NORTH ROAD & STATE STREET <br />Olsson <br />IN•fiFNN 1 <br />amusE ill <br />Cwwmpmft <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE, THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />_C3\ONpL CI V/4 F <br />'* _1� <br />a GREGORY T. A <br />SEIB <br />E-15150 <br />-Is*anal �P <br />OF NE8PP5 <br />GENERAL NOTES <br />