My WebLink
|
Help
|
About
|
Sign Out
Browse
202101887
LFImages
>
Deeds
>
Deeds By Year
>
2021
>
202101887
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 10:41:10 AM
Creation date
3/8/2021 10:30:14 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202101887
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ir- <br />go <br />(O <br />O <br />C <br />C) <br />al <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT -------------------------------------• <br />EXISTING AERIAL FIBER <br />BORED CONDUIT..................................................................... <br />TRENCHED CONDUIT................................................................... <br />QUANTITY <br />NEW AERIAL FIBER <br />LF. <br />NEW AERIAL FIBER, OVERLASH <br />TRACER WIRE <br />4 •°aE• <br />MESSENGER CABLE <br />ROCK / p6bd�.. ooa <br />HOSE CLAMPS •0..5dp4g \FABRIC <br />NO CITY RECIPIENT FIBER......................................................••••• <br />EXISTING CONDUIT ------------------------------------- <br />EXISTING SIGNAL CONDUIT --------------------------------- <br />ROW <br />FIBER, 96S.UNDERGROUND SLACK STORAGE <br />NEW PULL BOX <br />PULL BOX INSTALLATION <br />NEW PEDESTAL <br />�{ <br />NEW POLE <br />Q <br />NEW DOWN GUY <br />-1 <br />NEW RISER <br />NEW SLACK SPAN <br />Efi <br />NEW SLACK LOOP <br />CO <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />OO <br />EXISTING SLACK LOOP <br />00 <br />EXISTING SPLICE CASE <br />C <br />EXISTING MANHOLE <br />Q <br />SIGN <br />__Q_ <br />BARRICADE <br />w w w <br />DRUM <br />BORE PIT <br />❑ <br />ARROW PANEL <br />RT <br />CABLE AND CONDUIT DESIGNATIONS <br />8 B is Conduit Bored (ie..3" B) <br />C is conductor (ie.. 3/C) <br />CC is Coaxial Cable <br />CCC is Camera Control Cable <br />CDC is Camera Detector Cable <br />CG is Circuit Ground <br />CPC is Camera Power Cable <br />LL DB is Direct Buried <br />DMSC is Dynamic Message Sign Cable <br />EDC is Emergency Detector Cable <br />ETW is Electric Tracer Wire <br />EX is Existing <br />FI is Fabric Interduct <br />FLC is Fiber Locate Cable <br />FTW is Fiber Tracer Wire <br />INS is Install <br />INT is Intraduct <br />LC is Lead -In Cable <br />M is Conduit Mounted (ie..2" M) <br />MB is Main Line Conduit Group Bored (6) 1 1/4" <br />MM is Multi Mode Fiber Cable <br />MT is Main tine Conduit Group Trenched (6) 1 1/4" <br />NO is Number <br />OH is Over Head <br />PR is Pair of Communication (ie..6 PR) <br />REL is Relocate <br />REM is Remove <br />FIGS is Rigid Galvanized Steel <br />SC is Service Cable <br />SL is Street Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched (ie..3" T) <br />TW is Tracer Wire (black or green) <br />POLYMER CONCRETE ASSEMBLY <br />Ar. a. Tr <br />s w rnrc3TYim <br />Me. fon. SM,wq q.Mvw. (SPeGIr <br />a .t ad.)wi~ <br />LOAD VATe <br />k ftrw T,04-P."L.L So—& <br />cpbm. q <br />•%%AX 66 <br />•ASTM C 667 <br />• AINSMTE n <br />FEATURM <br />• usoA6us APt•.w <br />•Cann 6..YgrM sa <br />- `A•va a,.. naw <br />AddIII Fiat r.,nrMA <br />w.61../.w LM....w <br />offfs Tcr ��... <br />' ror.rcwa. Mtc, <br />Inside Dimensions <br />Lags I waa LT.o. i <br />j aTw,e• ,.-... 7, ,y,r �.r <br />UPN PULL BOX, 24"X36"X36" <br />REV A7 <br />AVOID WALK OR DRIVE <br />QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 2" B <br />LF. <br />1,602 <br />TRACER WIRE <br />4 •°aE• <br />Clfr PARALLEL <br />Ow:°�°•.:° <br />TO LID '#o yo^SdsEBo_ ROCK <br />ROCK / p6bd�.. ooa <br />HOSE CLAMPS •0..5dp4g \FABRIC <br />FABRIC�� L <br />' <br />° eC"°• 'g°°eded dy <br />•ob., •o�q;:� -'+:° <br />LF. <br />a._x_�b 5to�ob•°•o bpo <br />FIBER, 96S.UNDERGROUND SLACK STORAGE <br />UPN <br />PULL BOX INSTALLATION <br />SUMMARY OF <br />QUANTITIES <br />ITEM <br />UNIT <br />QUANTITY <br />CONDUIT, 2" B <br />LF. <br />1,602 <br />TRACER WIRE <br />LF. <br />1,952 <br />UPN PULL BOX <br />EA. <br />3 <br />FIBER, 96 SM, UNDERGROUND <br />LF. <br />1,952 <br />FIBER, 96S.UNDERGROUND SLACK STORAGE <br />LF. <br />420 <br />*ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.` <br />PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILITIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A. FORTY-TWO (42) INCHES IN SOIL, <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW LINE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48)INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LINE, AND <br />E. MAINTAIN A MINIMUM OF 24" OF VERTICAL & HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />Date: 12\16\2020 uramr IMn <br />,Checked: STS <br />PROJECT: 26071 <br />GRAND ISLAND PUBLIC SCHOOLS <br />EARLY LEARNING CENTER <br />2206 N. WEBB ROAD <br />ols-wn <br />IIIMaanNw l <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE, THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />\ONpL *CI V//� <br />5 F <br />5 <br />a GR ORY T. p <br />SEIB <br />E-15150 <br />sT 1a-16 - 0-40 <br />ATF OF NE8PP5 <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.