My WebLink
|
Help
|
About
|
Sign Out
Browse
202101229
LFImages
>
Deeds
>
Deeds By Year
>
2021
>
202101229
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 10:43:04 AM
Creation date
2/12/2021 10:09:35 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202101229
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
LEGEND OF SYMBOLS <br />EXISTING CONDUIT --------------------mmmmmmmmm--------- <br />EXISTING AERIAL FIBER <br />TEM <br />BORED CONDUIT..................................................................... <br />TRENCHED CONDUIT ................................................................... <br />CONDUIT, 2" B <br />NEW AERIAL FIBER <br />182 <br />TRACER WIRE <br />NEW AERIAL FIBER, OVERLASH <br />182 <br />BUILDING ENTRANCE <br />MESSENGER CABLE <br />1 <br />FIBER, 96 SM, UNDERGROUND <br />NO CITY RECIPIENT FIBER........................••••.•.•.•.•...•.•.•.•.•.•.•.•.•.•. <br />182 <br />EXISTING CONDUIT ------------------------------------- <br />LF. <br />180 <br />EXISTING SIGNAL CONDUIT --------------------------------- <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />Z <br />NEW POLE <br />O <br />NEW DOWN GUY <br />—� <br />NEW RISER <br />NEW SLACK SPAN <br />E <br />NEW SLACK LOOP <br />00 <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />OO <br />EXISTING SLACK LOOP <br />OO <br />EXISTING SPLICE CASE <br />W) <br />EXISTING MANHOLE <br />Q <br />SIGN <br />--a— <br />BARRICADE <br />w w <br />DRUM <br />OO <br />BORE PIT <br />❑ <br />ARROW PANEL <br />F_<71 <br />CABLE AND <br />CONDUIT DESIGNATIONS <br />B is Conduit Bored (ie..3" B) <br />LC is Lead -In Cable <br />C is conductor (ie.. 3/C) <br />M is Conduit Mounted (ie..2" M) <br />CC is Coaxial Cable <br />MB is Main Line Conduit Group Bored (6) 11/4" <br />CCC is Camera Control Cable <br />MM is Mufti Mode Fiber Cable <br />CDC is Camera Detector Cable <br />MT is Main Line Conduit Group Trenched <br />(6) 1 1/4" <br />CG is Circuit Ground <br />NO is Number <br />CPC is Camera Power Cable <br />OH is Over Head <br />DB is Direct Buried <br />PR is Pair of Communication (ie..6 PR) <br />DMSC is Dynamic Message Sign Cable <br />REL is Relocate <br />EDC is Emergency Detector Cable <br />REM is Remove <br />ETW is Electric Tracer Wire <br />FIGS is Rigid Galvanized Steel <br />EX is Existing <br />SC is Service Cable <br />FI is Fabric Interduct <br />SL is Street Light <br />FLC is Fiber Locate Cable <br />SM is Single Mode Fiber Cable <br />FTW is Fiber Tracer Wire <br />T is Conduit Trenched (ie..3" T) <br />INS is Install <br />TW is Tracer Wire (black or green) <br />INT is Intraduct <br />SUMMARY OF QUANTITIES <br />TEM <br />UNIT <br />QUANTITY <br />CONDUIT, 2" B <br />LF. <br />182 <br />TRACER WIRE <br />LF. <br />182 <br />BUILDING ENTRANCE <br />EA. <br />1 <br />FIBER, 96 SM, UNDERGROUND <br />LF. <br />182 <br />FIBER 96 SM UNDERGROUND SLACK STORAGE <br />LF. <br />180 <br />'ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES ARE <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES DO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.' <br />PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILITIES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOIL, <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW LINE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48)INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW UNE, AND <br />E. MAINTAIN A MINIMUM OF 24" OF VERTICAL & HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4, ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />Date: 12\21\2020 yawn:l m^ <br />Checked: STS <br />PROJECT:24212-TABITHA GRAND ISLAND I <br />904 CONCORD AVENUE <br />Olsson <br />w�Nw 1 <br />PRIOR TO CONSTRUCTION: I <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE, THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />�Cl\QNPL CI V// <br />a GREGORY T. A <br />SEIB <br />E-15150 <br />13-a*aoao <br />ATF OF NEB�Pc' <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.