My WebLink
|
Help
|
About
|
Sign Out
Browse
202010107
LFImages
>
Deeds
>
Deeds By Year
>
2020
>
202010107
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 10:43:17 AM
Creation date
12/28/2020 11:56:44 AM
Metadata
Fields
Template:
DEEDS
Inst Number
202010107
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
r <br />O <br />Cl <br />DIRECTION OF ENGINEERING — <br />70' <br />m <br />Q <br />\- PLOW (3) 1.25" SDR -11 - 390' <br />PLACE VIAERO FIBER - 390' <br />40' UTILITY EASEMENT <br />_51—V15' Stw . acw <br />29'- - <br />-EOP EOP EOP EOP EOP <br />-22'---I WILDWOOD DRIVE <br />14 <br />E?+00 EOF14+00 EOP-15+00—EOP-16+00 —Ef <br />R/W—�R/W— <br />°o STA. 16+50 <br />PROPOSED BORE PIT <br />(RESTORE TO CITY SPECIFICATIONS) <br />STA. 12+60 <br />—PROPOSED BORE PIT <br />(RESTORE TO CITY SPECIFICATIONS) <br />DIRECTIONAL BORE (3) 1.25" SDR -11 - 50' <br />PLACE VIAERO FIBER - 50' <br />17+00 <br />DIRECTIONAL BORE (1) 4" HDPE/80 - 175' <br />PLACE (3) 1.25" SDR -11 -175' <br />PLACE VIAERO FIBER - 175' <br />DIRECTIONAL BORE (1) 4" HDPE/80 - 115' <br />PLACE (3) 1.25" SDR -11 <br />\_ PLACE VIAERO FIBER - 115' PLOW (3) 1.25" SDR -11 - 265' <br />TO BE PERMITTED PLACE VIAERO FIBER - 265' <br />70' BY OTHERS 40' UTILITY EASEMENT <br />E -/-y E----- ---- E--- - E----- E----- E---- <br />SEVSEW W SEW 15' —SEW— <br />r- <br />EW— <br />... r 29' <br />EOP E -0P SOP EOP EO� <br />_WILDWOOD DRIVE <br />18+00 -EOP 19+0� 2r+00 R/W'r E 22+0R0 W�0 23R 00—� <br />STA. 21+35 UNION PACIFIC RAS <br />PROPOSED BORE PIT <br />(RESTORE TO CITY SPECIFICATIONS) <br />WOODED <br />AREA <br />MATERIAL LIST <br />A <br />UNIT <br />UNIT DESCRIPTION <br />ESTIMATED ACTUAL <br />FT <br />VIAERO (1) 4" HDPE/80 <br />290 <br />FT <br />VIAERO (3) - 1.25" SDR -11 <br />995 <br />FT <br />VIAERO FIBER <br />995 <br />DIRECTIONAL BORE (1) 4" HDPE/80 - 115' <br />PLACE (3) 1.25" SDR -11 <br />\_ PLACE VIAERO FIBER - 115' PLOW (3) 1.25" SDR -11 - 265' <br />TO BE PERMITTED PLACE VIAERO FIBER - 265' <br />70' BY OTHERS 40' UTILITY EASEMENT <br />E -/-y E----- ---- E--- - E----- E----- E---- <br />SEVSEW W SEW 15' —SEW— <br />r- <br />EW— <br />... r 29' <br />EOP E -0P SOP EOP EO� <br />_WILDWOOD DRIVE <br />18+00 -EOP 19+0� 2r+00 R/W'r E 22+0R0 W�0 23R 00—� <br />STA. 21+35 UNION PACIFIC RAS <br />PROPOSED BORE PIT <br />(RESTORE TO CITY SPECIFICATIONS) <br />WOODED <br />AREA <br />0 <br />0 <br />N <br />H <br />U) <br />W <br />Fn <br />W <br />Z <br />J <br />2 <br />U <br />H <br />Q <br />0 50' 100' <br />SCALE: 1"=100' <br />I nr.n!ar, <br />-a- <br />LABOR LIST <br />A <br />UNIT <br />UNIT DESCRIPTION <br />ESTIMATED ACTUAL <br />FT <br />DIRECTIONAL BORE (1) 4" HDPE/80 <br />290 <br />FT <br />DIRECTIONAL BORE (3) 1.25" SDR -11 <br />50 <br />FT <br />PLOW (3) 1.25" SDR -11 <br />655 <br />FT <br />PLACE (3) - 1.25" SDR -11 <br />290 <br />FT <br />IPLACE VIAERO FIBER <br />995 <br />0 <br />0 <br />N <br />H <br />U) <br />W <br />Fn <br />W <br />Z <br />J <br />2 <br />U <br />H <br />Q <br />0 50' 100' <br />SCALE: 1"=100' <br />I nr.n!ar, <br />-a- <br />STREET SIGN <br />A <br />FIRE HYDRANT <br />O <br />WATER METER <br />® <br />U1ILITY VALVE <br />® <br />UTILITY POLE <br />Qo <br />UTILITY MANHOLE <br />C3 <br />UTILITY HANDHOLE <br />® <br />ELECTRICAL/UTILITY CABINET <br />® <br />TELEPHONE PED - CROSS BOX <br />® <br />PROPOSED VIAERO MANHOLE <br />PROPOSED VIAERO HANDHOLE <br />O <br />STORM INLET <br />® <br />STORM GRATE <br />>--< <br />CULVERT <br />TREE <br />■ <br />CUT -RESTORE <br />LINETYPES <br />�••�• ...... <br />CONDUIT -PERMITTED BY OTHERS <br />_••_••_••_••_ <br />CONDUIT-(DIRECDONAL BORE) <br />_••_••_••_••_ <br />CONDIAT-(PLOW) <br />CONDUIT -(TROD) <br />—R/w— <br />RIGHT-OF-WAY <br />—EaP— <br />EDGE OF ASPHALT <br />— — — <br />— EDGE OF GRAVEL <br />EDGE OF SIDEWALK <br />x <br />FENCE-00STING <br />--- C --a— <br />GUARD RAIL-EWIING <br />RAILROAD-EbSTNG <br />---c- <br />GAS -DUSTING <br />E <br />UNDERGROUND ELECTRIC-EIOSTNG <br />r <br />TELEPHONE-DQSTNG <br />�— <br />STORM SEWER -DUSTING <br />SANITARY SEWER -DUSTING <br />------ �m <br />STEAM-DOSTING <br />w <br />WATER-DXSTING <br />BU&MG <br />CMCOMMUNICATION DESIGN GROUP CONSULTANTS. LLL <br />12974 ELKHORN CIRCLE BROOMFIELD. CO 80021 <br />PHONE -303.548.1379 <br />9RwN ar. BWL <br />CNFfJ® BY. TDM <br />APPWM 96 <br />� 7 <br />VIAERO <br />Fiber Networks, LLC <br />1224 W. Platte Am P%I-970-487-3142 <br />Fort MaPgaa• CO 80701 WW.WIFRO.00M <br />W%dUm <br />am"— <br />SITE A00RM <br />GRAND ISLAND - DONIPHAN <br />CITY OF GRAND ISLAND <br />COVER SHEET <br />FU NYE SNRT: <br />v_cLo"o"�_an a c.�a �a.ro sam.av <br />WE OW11011, 10116/20 <br />WE NrAm — 03 <br />7AE 1'=100' <br />PIDP WE' 10/21/20 SNRF. 03 . 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.