My WebLink
|
Help
|
About
|
Sign Out
Browse
202002430
LFImages
>
Deeds
>
Deeds By Year
>
2020
>
202002430
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2020 12:19:12 PM
Creation date
4/21/2020 12:08:13 PM
Metadata
Fields
Template:
DEEDS
Inst Number
202002430
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
202002430 <br />• <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />BORED CONDUIT <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER. OVERIASH <br />MESSENGER CABLE <br />NO CRY RECIPENT FIBER <br />EXISTING CONDUIT <br />EXISTING SIGNAL CONDUIT • <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EASING UTILITY POE <br />EXISTING SLACK LOOP <br />EXISTING SPl10E CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />58) <br />() <br />I) <br />8 s Condon Bored 0_7 B) <br />C is conductor (ie.. 3/C) <br />CC s 38.801) Cable <br />CCC a Camera Control Cable <br />CDC s Camera Detector Cade <br />CG M Comma Ground <br />CPC a Camera Power Cable <br />D8 is Drect Buried <br />DMSC a Dynamic Message Sign Gable <br />EDC s Emergency Detector Cade <br />E1 W a Elect0c Tracer WYe <br />EX s Easting <br />FI s Fabnc Inlerduct <br />FLC a Fber Louts Cade <br />FTW s Fber Tracer Me <br />INS a MOM <br />INT s Intraduct <br />LC b Lead -In Cable <br />M is Conduil Mounted 0.7 N <br />MB s Mon Line Conduit Group Bored (8) 1 1/4" <br />MI 'a MJG Mode Fiber Gable <br />MT is Main Line Conduit Group Trenched (6) 1114' <br />NO is Number <br />OH 'a Over Head <br />RR s Par of Communication Ile_ 6 PR) <br />REL is Relocate <br />RBA a Remove <br />6GS is Rigid Galvanized Steal <br />5C s Service Cade <br />SL s Street Ugh( <br />SM s Sngle Mode Fiber Cable <br />T is Condon Trenched (le.3 1) <br />w s Tracer Woo (daa or green) <br />BOCILILACOBCHElf ASSEMBLY <br />neyloosas <br />r <br />10061 Ormenuone <br />UPN PULL. 80X 2,7836736" <br />AVID WMA OR ONE <br />ROX <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />UNIT <br />QUANTITY <br />CCCAND3)3 If B <br />LF <br />623 <br />TRACER ',1RE <br />LF. <br />623 <br />BUILDING ENTRANCE <br />FA <br />LPN PULL BOX <br />EA <br />1 <br />FIBER. BS 50 UNDERGROUND <br />LF. <br />623 <br />FIBER 96 5h1, UNDERGROUND SLACK STORAGE <br />If <br />280 <br />'ALL FIBER (UNDERGROUND/AERIAL) AND CONDUIT (BORE/TRENCH/PLOW) QUANTITIES AR <br />MEASURED AS LINEAL FEET BETWEEN CENTERS OF PULL BOXES, CABINETS, AND POLES. <br />QUANTITIES CO NOT ACCOUNT FOR ELEVATION CHANGE OR SLACK.• <br />PROJECT NOTES <br />t THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTIUTY <br />FACLITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILMES, WHETHER SHOWN OR NOT, WILL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION NALL BE PERMITIED N THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />O UNLESS AGREED TO N VATTING N ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACIUTIES SHALL BE, AT A MINIMUM, AS FOLLOWS'. <br />A FORTY-TWO IAA INCHES N SOIL, <br />B. FORTY-TWO (4 INCHES BELOW A PROJECTED SLOPE FROM THE FLOW UNE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT 148) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY TO THE TOP OF THE INSTALLATION. <br />O FORTY-EIGHT (48) INCHES UNDER A STOW, NATER OR CREEK CHANNEL <br />DESIGN FLOW UNE, AND <br />E MAINTAIN A MINIMUM OF 31 CF VERTICAL 8 HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES N SIDEWALK PANELS Will. REQUIRE FUU. PANEL REPLACEMENT. <br />4 ANY CUT OR POTHOLE N A CONCRETE STREETS PANEL NLL REQUIRE FULL <br />PANEL REPLACEMENT. <br />5 ANY CUT OR POTHOLE N A ASPHALT STREET LANE WALL REQUIRE SEAM TO <br />SEAM ASPHALT MILUNG AND REPLACEMENT. <br />MULCT M. 01 TI$ <br />Data 1111112.111 10.NT. NR <br />017-0078 G1e <br />'_ ... d0ea.8 SIS <br />1800.006 O <br />PROECT 2404GAT&T <br />iib W MI 011558 <br />olsson <br />Unite <br />MATE Lkl. <br />ROMPS MUM. <br />NawaYNbeir . <br />I•YIBYMae last <br />PRIOR TO CONSTRUCTION. <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE. <br />ELECTRIC. GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AN0 <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES LAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE. THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. TT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.