Laserfiche WebLink
(c) Vertical and horizontal separations between telecommunications facilities and other <br />facilities shall be maintained as required by the NESC Section 32 Underground Conduit Systems. <br />Conduit systems for telecommunications facilities shall be separated from conduit systems for <br />power supply systems by: <br />(1) 3 inches of concrete <br />(2) 4 inches of masonry <br />(3) 12 inches of well -tamped earth <br />Warning Tape <br />(a) A detectable orange colored cable warning tape shall be placed 12 to <br />18 inches above, the conduit in the trench. <br />Hand -holes <br />(a) All cavities required for cable pulling purpose shall be constructed as <br />load bearing Hand -holes. <br />(b) Hand -holes shall be placed at as specified on plans and approved by Viaero.. <br />In no case shall conduit bend radius exceed 180 degrees between structures. <br />Hand -holes shall be either a 30'x48"x24" precast composite concrete or a 30'x48'x36" <br />precast composite concrete. Refer to project detail sheet 07 for specifications. <br />Separations from Other Public Utilities and Drainage Facilities <br />(a) Parallel separations are required to satisfy standards for utility trenching <br />excavations and to provide for adequate maintenance operations. <br />(1) The minimum parallel separation between telecommunications conduit <br />and water pipe or drainage pipe and other pipe with a depth of cover of less than <br />6 feet shall be 5 feet. <br />(2) The minimum parallel separation between telecommunications conduit <br />and wastewater pipe or other pipe with a depth of cover of more than 6 feet shall <br />be 10 feet. <br />(b) Vertical separation at utility crossings shall be as follows: <br />(1) The minimum vertical separation between telecommunications conduit <br />and City public utilities shall be 6 inches. <br />All crossings of natural and improved drainage ways, and irrigation ditches, <br />shall meet the following conditions: <br />(1) Telecommunications conduit shall be placed a minimum 48 inches below the invert <br />of the drainage way or ditch. This minimum depth of cover shall apply whether or not the <br />drainage way is an open system or contained within a culvert. <br />(2) The telecommunications conduit shall be placed in a SDR -11 <br />to accomidate placed conduits. When the drainage way or ditch is an open system, the sleeve <br />shall extend a minimum horizontal distance of 10 feet beyond each side of the drainage way, measured <br />from top of bank to top of bank. <br />(3) When the drainage way or ditch is in a culvert, and the culvert opening is greater <br />than 5 feet, the sleeve shall extend a minimum horizontal distance of 5 feet beyond each <br />side of the culvert, or shall extend a minimum horizontal distance equal to the vertical depth of <br />the culvert, measured from the culvert invert to the final ground surface above the culvert. <br />BERRY W. LO <br />VLAERO <br />Fi#err Nelwrorks: LLG <br />1724 l Mow M MI -W467- <br />Erl Mvgo� a NIAI wtulPaaGw <br />PROJECT NOTES <br />LEGEND <br />v <br />STREET SIGN <br />,q. <br />FIRE HYDRANT <br />O <br />WATER METER <br />® <br />UTILITY VALVE <br />® <br />UTILITY POLE <br />Qo <br />UTILITY MANHOLE <br />D <br />UTILITY HANDHOLE <br />IM <br />ELECTRICAL/UTILITY CABINET <br />M <br />TELEPHONE PED - CROSS BOX <br />® <br />PROPOSED VUERO MANHOLE <br />PROPOSED NAERO HANDHOLE <br />D <br />STORM INLET <br />■ <br />STORM GRATE <br />>-- <br />CULVERT <br />Q <br />TREE <br />■ <br />CUT -RESTORE <br />LINETYPES <br />CMV-(PLGr / TM CH) <br />—•• •— maul-DREcmwBX <br />—.i.— M&M -Gr -MY <br />E&S OF nmu T <br />Ear OF MOn <br />EGGS OF smwc <br />— PENCE-OMM <br />- <br />— GUAM P i-DMW <br />rtuumw-MIM <br />_. ._. CIS-DWM <br />— <br />_.___.._`. <br />— LODU RGIRN EILCWG-EASING <br />_._._....... IUMM-EMSING <br />a <br />STM San -EASING <br />.._..._.sus_._.._.... <br />STEW SEEK-EImING <br />-- _�-- <br />SiENFEASTM <br />— Mua-DSING <br />&Malt <br />BERRY W. LO <br />VLAERO <br />Fi#err Nelwrorks: LLG <br />1724 l Mow M MI -W467- <br />Erl Mvgo� a NIAI wtulPaaGw <br />PROJECT NOTES <br />