Laserfiche WebLink
STAKING SHEET - UNDERGROUND Company: Nebraskal-ink Exchange: Grand Island <br />Main Point <br />Page 1A <br />Enter existing HH1 <br />Add ground rod and matchstick to <br />HH1. This is a new splice point. <br />Bore 2" HDPE duct approximately <br />360 feet North. <br />Set new HH2 with ground rod and <br />fiber marker. Leave 100 foot slack. <br />Bore 1.25' HDPE duct approximately <br />160 ft to MPOE (see 1 B) <br />Pull fiber from MPOE to <br />communications room West <br />of MPOE through drop ceileing <br />Leave 50 fee slack loop at HH1 and <br />30 feet slack loop in Comm room for <br />splicing. <br />Page 113 <br />IMPOE area show as an elipse on <br />building. <br />