Laserfiche WebLink
201903054 <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER, OVERIRSH <br />MESSENGER CABLE <br />EXISTING CONDUIT <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING LTRUTV POLE <br />EXISTING SLACK LOOP <br />EXISTING SPL. ICE CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />0 <br />I'<<I <br />B is Conduit Bored (ie..3' B) <br />C is conductor (ie.. 3/C) <br />CC is Coaxial Cable <br />CCC is Camera Control Cable <br />CDC is Camera Detector Cable <br />CO Is Circuit Ground <br />CPC is Camera Power Cable <br />DB is Direct Buried <br />DMSC Is Dynamic Message Sign Cable <br />EDC is Emergency Detector Cade <br />ETW Is Electric Tracer Wire <br />EX is bdsling <br />Fl is Fabric Interduct <br />FLC is Fiber Locale Cable <br />FTW is Fiber Tracer Wire <br />INS Is Install <br />INT is Mraduct <br />LC is Lead -In Cable <br />M is Conduit Mounted (1e..2" M) <br />MB B Main Life Conduit Group Bored (6)1 1/4' <br />MM N Multi Mode Elbe, Cable <br />MT is Main Lea Conduit Group Trenched (6) 1 I/4' <br />NO is Number <br />OH Is Over Head <br />PR is Pei of Communication (10.6 PR) <br />REL k Relocate <br />REM is Remove <br />RGS Is Rlglo Galvanized Steel <br />SC is Sentra Cable <br />SL is Sheet Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched (Ie..3' T) <br />TW is Tracer Wire (black or (green) <br />PCA243636-00006 <br />KAMM COTWATETE MUM. <br />',o.n.o.., <br />3.3.1•1 OMkm*. <br />�a <br />anbm <br />IAm Dnmevs <br />wow ow. <br />UPN Pull Box, 24"x36"x36" <br />PROJECT NOTES <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />UNIT <br />QUANTITY <br />,ITEM <br />CONDUIT 1.8 B <br />LF. <br />2,241 <br />TRACER WIRE <br />LF <br />2,241 <br />PULL BOX 24'X36 X36' <br />EL <br />3 <br />FIBER 144 SR UNDERGROUND <br />LF. <br />2,241 <br />FIBER 144 SM, UNDERGROUND SLACK STORAGE <br />LF <br />400 <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTIUIES, WHETHER SHOWN OR NOT.MLL BE LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED IN THE AREA OF THE UNDERGROUND <br />UTIUIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY. THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE. AT A MINIMUM, AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOIL. <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW UNE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE, <br />C. FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />OF SAID ROADWAY 10 IHE TOP OF THE INSTALLATION, <br />D. FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LINE. AND <br />E. MAINTAIN A MINIMUM OF 24' OF VERTICAL A. HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3. ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE N A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />ANY CUT OR POTHOLE N A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEW ASPHALT MILLING AND REPLACEMENT. <br />PROJECT NO. <br />SHEET NO, <br />017-00)B <br />G.1 <br />Dare: 04,29,2019 <br />Dram'. TAR <br />Crecxed' STS <br />Ammo& RD <br />PROJECT: 19589 HUSKER HIGHWAY <br />ROAD MOVE ADD1110N <br />Olsson <br />Unite <br />rawrt [Ant. <br />=awe <br />past <br />CalWwtes. <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />Fl ECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTIUTES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INf ORMAIION AND <br />THEREFORE. THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBIUTY OF THE <br />INDMDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />ANO DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SWILL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />GENERAL NOTES <br />