My WebLink
|
Help
|
About
|
Sign Out
Browse
201901614
LFImages
>
Deeds
>
Deeds By Year
>
2019
>
201901614
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2019 4:31:10 PM
Creation date
3/20/2019 4:19:15 PM
Metadata
Fields
Template:
DEEDS
Inst Number
201901614
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
201901614 <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />TRENCHED CONDUIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER, OVERLASH <br />MESSENGER CABLE <br />EXISTING CONDUIT <br />• PCA243636-00006 <br />vgLr..ex t. .PItrt wltwlH <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING UTILITY POLE <br />EXISTING SLACK LOOP <br />EXISTING SPI ICE CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND <br />CONDUIT DESIGNATIONS <br />B is Conduit Bored (ie..3' B) <br />C h conductor (ie.. 3/C) <br />CC h Coaxial Cade <br />CCC h Camera Control Cable <br />CDC Is Camera Detector Cable <br />CG is Circuit Ground <br />CPC is Camera Power Cade <br />DB is Direct Buried <br />[MSC h Dynamic Message Sign Cable <br />EDC is Emergency Detector Cable <br />ETW Is Electric Tracer Wire <br />EX Is Existing <br />FI is Fabric Idarduct <br />FLC is Fiber Locale Cabe <br />FTW is Fiber Tracer Wire <br />INS Is Install <br />INT is Intraduct <br />LC is Lead -In Cade <br />M is Conduit Mounted (Ie..2" M) <br />MB is Main Line Conduit Group Bored (6) 1 1/4" <br />MM is Multi Mode Fiber Cable <br />MT is Main Line Conduit Group Trenched (6) 1 1/4" <br />NO is Number <br />01-1 is Over Head <br />PR is Pair of Communication (..6 PRI <br />REL Is Relocate <br />REM is Rernore <br />RGS Is Rigid Galvanized Steel <br />SCh Service Cade <br />SL is Street Light <br />SM is Single Mode Fiber Cable <br />T is Conduit Trenched (ie..3" T) <br />TW is Tracer Wire (black or green) <br />wre}o r <br />1.6.4614•1111. rrwnwlpx..r <br />11111141.11* <br />f� ase <br />+16mr1e4.r.l.. <br />Aurrlrr.Amw.�wr <br />Awl* Dimensions <br />w. r <br />UPN PULL BOX 24"X36'X36 <br />ADA Ar <br />UPN PULL BOX INSTALLATION <br />SUMMARY OF QUANTITIES <br />/TEM <br />UNIT <br />QUANTITY <br />CONDUIT Ts R <br />LF. <br />1 062 <br />TRACER W1RE <br />LF. <br />1062 <br />BUILDING ENTRANCE <br />EA. <br />RUL_ BOX 24"X36 X36" <br />EA <br />3 <br />FIBER 26 SM UNDERGROUND <br />LE <br />1062 <br />FIBER 56 SM UNDERGROUND SLACK STORAGE <br />LE. <br />420 <br />PROJECT NOTES <br />1. THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS, UNDERGROUND <br />UIILIIIES. WHEIHLR SHOWN OR NOT, WILL BE LOCATED AND F LAGGED <br />BY THE UTILITIES UPON THE REOUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED M THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTILITIES AND CONSTRUCTIONS. <br />2. UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM. AS FOLLOWS: <br />A FORTY-TWO (42) INCHES IN SOIL. <br />B. FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW LINE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE. <br />C. FORTY-FIGIIT (40) INCHES UNDER A ROADWAY MEASURED FROM THF SURFACE <br />01 SAID ROADWAY 10 THE IOP OF THE INSIALLAIION, <br />D. FORTY-EIGHT (40) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LINE. AND <br />E. MAINTAIN A MINIMUM OF 24" OF VERTICAL & HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />3 ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />4. ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />S. ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT, <br />PROJECT N0. <br />SHEET NO. <br />017-0070 <br />Date: 0131\2019 <br />Drain <br />Csecxed <br />Approved <br />PTA <br />TOR <br />(PS <br />PR0JFCT:16658 GP( NC1NFFRING LOC A <br />306 W. 340 SIRFFT 81 <br />Olsson <br />Unite <br />MILIMIt <br />MORAYS MON <br />GISMO= lesi dig <br />YGIWOYWI{ <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />ELECTRIC, GAS MAINS, CARLE <br />TELEVISION AND OTHER UTILITIES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTIUTIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE TN1 OHMAIION AND <br />THEREFORE, THEIR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY, IT IS THE <br />RESPONSIBILITY OF THE <br />INDMDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CTTY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />GENERAL NOTES <br />
The URL can be used to link to this page
Your browser does not support the video tag.