Laserfiche WebLink
201901613 <br />LEGEND OF SYMBOLS <br />EXISTING CONDUIT <br />EXISTING AERIAL FIBER <br />TRENCHED CONOIIT <br />NEW AERIAL FIBER <br />NEW AERIAL FIBER. OVERLPSH <br />MESSENGER CABLE <br />EXISTING CONDUIT <br />EXISTING SIGNAL CONDUIT <br />ROW <br />NEW PULL BOX <br />NEW PEDESTAL <br />NEW POLE <br />NEW DOWN GUY <br />NEW RISER <br />NEW SLACK SPAN <br />NEW SLACK LOOP <br />EXISTING PULL BOX <br />EXISTING PEDESTAL <br />EXISTING WILILY POLE <br />EXISTING SLACK LOOP <br />I-XISIING SPLICE CASE <br />EXISTING MANHOLE <br />SIGN <br />BARRICADE <br />DRUM <br />BORE PIT <br />ARROW PANEL <br />CABLE AND CONDUIT DESIGNATIONS <br />V <br />4 <br />f>i <br />CO <br />0 <br />0 <br />CO <br />O <br />0 <br />B is Conduit Bored (1e..3' B) <br />C is conductor (e.. 3/C) <br />CCN Coaxial Cade <br />CCC is Carrera Control Cable <br />CDC 0 Camera Detector Cable <br />CG is Circuit Ground <br />CPC Is Camera Payer Cable <br />00 is Direct Buried <br />DMSC Is Dynamic Message Sign Cade <br />LOC is Emergent' Detector Cable <br />ETW Is Electric Tracer IWe <br />EX Is Existing <br />FI 0 Fabric Interducl <br />FLC is Fiber Locate Cable <br />F1W 's Fiber Tracer Wire <br />INS is Install <br />INT is Intraduct <br />LC is Lead -In Cade <br />M 8 Conduit Mounted (e..2" M) <br />MB is Main Line Conduit Group Bored (6) 1 1/4" <br />MM Is Mute Mode Fiber Cable <br />MT is Main The Conduit Group Trended (6) 1 124" <br />NO is Number <br />Ol Is Over Head <br />PR is Pak of Comrnunkallon (ie.. 6 PR) <br />REL is Relocate <br />REM is Remove <br />RG5 le Rigid Galvanized Steel <br />SC is Service Cable <br />SL is Street Light <br />SM N Single Mode Fiber Cade <br />T Is Conduit Trenched (10..3" T) <br />TW is Tracer Wire (black or green) <br />SUMMARY OF QUANTITIES <br />[TrFM <br />UNIT <br />QUANTITY <br />FIBER 48 SM. UNDERGROUND <br />LF. <br />212 <br />FIRER 48 SM, UNDERGROUND SLACK STORAGE <br />IF. <br />100 <br />TRACER WARE <br />LF. <br />212 <br />DOWN GUY <br />EA <br />I IBI_R. 48 SM OVLRISt AD <br />LF <br />1 707 <br />FIBER, 48 SM OVERHEAD SLACK STORAGE <br />LF. <br />109 <br />PROJECT NOTES <br />THE LOCATIONS OF ALL AERIAL AND UNDERGROUND UTILITY <br />FACILITIES MAY NOT BE INDICATED ON THESE PLANS. UNDERGROUND <br />UTILITIES. WHE I HER SHOWN OH NOT, WILL BL LOCATED AND FLAGGED <br />BY THE UTILITIES UPON THE REQUEST OF THE CONTRACTOR. NO <br />EXCAVATION WILL BE PERMITTED 84 THE AREA OF THE UNDERGROUND <br />UTILITIES UNTIL ALL SUCH FACILITIES HAVE BEEN LOCATED AND <br />IDENTIFIED TO THE SATISFACTION OF ALL PARTIES, THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOB PROTECTION OF ALL UNDERGROUND AND <br />AERIAL UTIUTIES AND CONSTRUCTIONS. <br />UNLESS AGREED TO IN WRITING IN ADVANCE BY THE CITY, THE DEPTH OF <br />INSTALLED FACILITIES SHALL BE, AT A MINIMUM. AS FOLLOWS: <br />FORTY-TWO (42) INCHES IN SOIL. <br />FORTY-TWO (42) INCHES BELOW A PROJECTED SLOPE FROM THE FLOW UNE <br />OF A DITCH AT A THREE (3) HORIZONTAL AND ONE (1) VERTICAL SLOPE. <br />FORTY-EIGHT (48) INCHES UNDER A ROADWAY MEASURED FROM THE SURFACE <br />Of SAID ROADWAY f0 THE IOP OF THE INSTALLATION, <br />FORTY-EIGHT (48) INCHES UNDER A STORM WATER OR CREEK CHANNEL <br />DESIGN FLOW LINE. AND <br />MAINTAIN A MINIMUM OF 24' OF VERTICAL B HORIZONTAL SPACING FROM <br />EXISTING UTILITIES. <br />ALL POTHOLES IN SIDEWALK PANELS WILL REQUIRE FULL PANEL REPLACEMENT. <br />ANY CUT OR POTHOLE IN A CONCRETE STREETS PANEL WILL REQUIRE FULL <br />PANEL REPLACEMENT. <br />ANY CUT OR POTHOLE IN A ASPHALT STREET LANE WILL REQUIRE SEAM TO <br />SEAM ASPHALT MILLING AND REPLACEMENT. <br />AERIAL FIBER INSTALLATION <br />I. INSTALL THE MESSENGER WITH CABLES TO SPECIFIED SAG AS SUBMITTED ON <br />COMM -SCOPE SAG DATA. <br />2. FIELD VERIFY ALL NEWLY INSTALLED CABLE/MESSENGER CLEARANCES ARE <br />CONSTRUCTED IN ACCORDANCE WITH THE NESC. <br />3. ALL ABANDONED BOLT HOLES ARE TO BE TREATED WITH WOOD PRESERVER <br />AND PLUGGED WITH SIMILAR MATERIALS AS STATED IN THE CONTRACT. <br />4. GROUNDING TO BE INSTALLED AS STATED IN THE CONTRACT. <br />PROJECT N0. <br />SHEET NO. <br />017-0078 <br />Daie, 02,207209 <br />'brawn PTA <br />Checked: TIM <br />Approval JPD <br />P CBEC".10659 CA FNGINFFRNG OC 7 <br />430 5 STUHR ROAD <br />olsson <br />Unite <br />MEM IMMO. <br />aY:.r <br />selnemee MIM <br />Itmelr simisla <br />i�Ym11�1/� <br />PRIOR TO CONSTRUCTION: <br />CALL 811 FOR LOCATION OF <br />UNDERGROUND TELEPHONE, <br />FI ECTRIC, GAS MAINS, CABLE <br />TELEVISION AND OTHER UTILIRES. <br />EXISTING UNDERGROUND AND <br />OVERHEAD UTILITIES AND <br />DRAINAGE STRUCTURES HAVE <br />BEEN PLOTTED FROM <br />AVAILABLE INFORMATION AND <br />THEREFORE, THOR LOCATIONS <br />MUST BE CONSIDERED <br />APPROXIMATE ONLY. IT IS THE <br />RESPONSIBILITY OF THE <br />INDIVIDUAL CONTRACTORS TO <br />EXACTLY LOCATE AND PROTECT <br />EACH EXISTING UTILITY BEFORE <br />AND DURING ACTUAL <br />CONSTRUCTION. <br />CONSTRUCTION SHALL MEET CITY <br />OF GRAND ISLAND STANDARD <br />CONSTRUCTION SPECIFICATIONS <br />AND STANDARD PLANS. <br />GENERAL NOTES <br />